Optimization of a diagnostic platform for oxidation-reduction potential (ORP) measurement in human plasma.
نویسندگان
چکیده
OBJECTIVES Oxidation-reduction potential (ORP) measurement can demonstrate the extent of oxidative stress in patients with severe illness and/or injury. A novel ORP diagnostic platform using disposable sensors (RedoxSYS) has been validated by comparison to mass spectrometry, but the optimal methods of sample handling for best performance of the device have not been described. METHODS We sought to optimize ORP measurement in human plasma under controlled conditions. We hypothesized that the anticoagulant, freeze-thawing, and storage duration would influence measured ORP levels. RESULTS The platform was sensitive to exogenous oxidation with hydrogen peroxide and reduction with ascorbic acid. Plasma anticoagulated with heparin was more sensitive to differences in ORP than plasma prepared in citrate. ORP measurements decreased slightly after a freeze-thaw cycle, but once frozen, ORP was stable for up to one month. DISCUSSION We confirm that ORP detects oxidative stress in plasma samples. Optimal measurement of plasma ORP requires blood collection in heparin anticoagulant tubes and immediate analysis without a freeze-thaw cycle.
منابع مشابه
Oxidation-reduction potential as a new marker for oxidative stress: Correlation to male infertility
Male infertility affects men worldwide. Oxidative stress (OS), characterized by an overabundance of reactive oxygen species (ROS) or a deficiency of antioxidants, is one of the major causes of male infertility. OS causes damage at the molecular level, which impairs lipids, proteins, and DNA. The cyclic cascade of redox reactions weakens sperm function which leads to poor semen parameters and ev...
متن کاملPower Plant Chemistry Measurement Advancements: Oxidation Reduction Potential
Measurements which show the potential for corrosion of a plant’s metallurgy due to interaction with the system water have gained in importance within the last two decades. Among the most successful of these measurements are those which measure an actual potential which is based upon the oxidation/reduction reactions taking place. The measurement of Oxidation Reduction Potential (ORP) has been u...
متن کاملMeasuring Techniques for Oxidation- Reduction Potential in High Purity Water
The measurement of Oxidation-Reduction Potential (ORP) can be used in the water/steam cycle of a power plant to infer information about system reactions to water chemistry. While the measurement of ORP is by no means a new measurement, the high purity water of the water/steam cycle is a relatively new application for ORP. This presents a challenge since little information is available on proper...
متن کاملA 24 h Delay in the Redox Response Distinguishes the most Severe Stroke Patients from Less Severe Stroke Patients
Methods: Oxidation reduction potential (ORP), a measure of the redox system, was assessed in plasma at admission and 24 h later in patients admitted with stroke symptoms (n=76). Overall differences in ORP between stroke patients and healthy controls were determined. Within stroke patients, changes in ORP as a function of hospital discharge status, modified Rankin scale and NIHSS were assessed u...
متن کاملRegulation of Denitrification Using Continually Measured ORP and pH Signal
The use of pH and oxidation-reduction potential (ORP) as control parameters for the nitrificationdenitrification process is compared and discussed. The signals were measured in a sequencing batch reactor activated sludge system and in a completely mixed activated sludge reactor. The termination of denitrification was clearly identified not only by an ORP signal, but also by a pH signal. However...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Redox report : communications in free radical research
دوره 23 1 شماره
صفحات -
تاریخ انتشار 2018