Comparative evaluation of nonradiometric BACTEC and improved oxoid signal blood culture systems in a clinical laboratory.

نویسندگان

  • C Daley
  • I Lim
  • J Modra
  • I Wilkinson
چکیده

The BACTEC NR660 blood culture system, which uses infrared spectroscopy to detect carbon dioxide generated by bacterial growth, was compared with the new medium formulation of the Oxoid Signal system. Two trials were conducted: a comparative study of 88 organisms in simulated blood cultures and a clinical trial of 3,321 paired patient blood culture samples. Both trials showed that overall the BACTEC system performed better in the recovery of organisms. The Oxoid system was unable to detect by signal the growth of the majority of yeasts, nonfermentative gram-negative bacilli, Neisseria meningitidis, Nocardia spp., and Corynebacterium jeikeium. There were no significant differences in the yield of Staphylococcus spp., members of the family Enterobacteriaceae, Streptococcus spp., or anaerobic organisms. BACTEC detected growth more quickly than did the Oxoid system; 61% of the isolates were detected by BACTEC at 24 h, while 49% of the isolates were detected by Oxoid. The Oxoid system had a high proportion (58.5%) of false-positives, compared with 7.7% for the BACTEC system. Despite the new medium formulation of the Oxoid system, its performance is still not equivalent to that of the BACTEC system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of agitation and terminal subcultures on yield and speed of detection of the Oxoid Signal blood culture system versus the BACTEC radiometric system.

In an initial evaluation, we found the Oxoid Signal blood culture system inferior to the BACTEC radiometric system for detection of some microorganisms causing septicemia (M. P. Weinstein, S. Mirrett, and L. B. Reller, J. Clin. Microbiol. 26:962-964, 1988). To determine whether modified processing of the Oxoid Signal blood culture system could improve its yield and speed of detecting positive c...

متن کامل

Effect of altered headspace atmosphere on yield and speed of detection of the Oxoid Signal blood culture system versus the BACTEC radiometric system.

The one-bottle Oxoid Signal blood culture system altered to provide a more aerobic bottle headspace was reassessed in a comparative study versus the two-bottle BACTEC radiometric system in 5,426 blood cultures. The BACTEC system detected more microorganisms (P less than 0.02), particularly anaerobes (P less than 0.05) and fungi (P less than 0.05).

متن کامل

Growth detection failures by the nonradiometric Bactec MGIT 960 mycobacterial culture system.

Mycobacterial growth in liquid culture can go undetected by automated, nonradiometric growth detection systems. In our laboratory, instrument-negative tubes from the Bactec MGIT 960 system are inspected visually for clumps suggestive of mycobacterial growth, which (if present) are examined by acid-fast smear analysis. A 3-year review demonstrated that ∼1% of instrument-negative MGIT cultures co...

متن کامل

Clinical comparison of isolator and BACTEC 660 resin media for blood culture.

The 10-ml Isolator system (E.I. du Pont de Nemours & Co., Inc., Wilmington, Del.) was compared with the BACTEC 16A-17A nonradiometric resin system (Johnston Laboratories, Inc., Towson, Md.) for isolation of organisms from 6,839 paired blood cultures. Equal volumes of blood (6 to 10 ml for each Isolator and 3 to 5 ml for each BACTEC bottle) were cultured in parallel in the two systems, and 600 i...

متن کامل

Controlled comparison of the BacT/Alert and BACTEC 660/730 nonradiometric blood culture systems.

In a collaborative study at three university hospitals, the recovery of microorganisms and the speed of detection of microbial growth by the BacT/Alert (Organon Teknika Corporation, Durham, N.C.) and BACTEC 660/730 (Becton-Dickinson Diagnostic Instrument Systems, Sparks, Md.) nonradiometric blood culture systems were compared. A total of 5,918 comparisons were made between BacT/Alert aerobic an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 28 7  شماره 

صفحات  -

تاریخ انتشار 1990