Fast Remaining Thickness Measurement Using a Laser Source Scanning Technique
نویسندگان
چکیده
Fast remaining thickness measurement using Lamb wave is presented for the purpose of maintenance of large structures like oil storage tanks and pipe networks. This study used a laser ultrasonic source to perform a high resolution remote scanning over aluminum plates with grooved and circular defects that were modeled on corrosions in plate-like structures. The antisymmetric A0 and symmetric S0 modes of Lamb wave were used to obtain information of the plate thickness from amplitude distributions over the scanned areas on plates. The amplitude distributions of A0 mode provide better thickness distributions that those of S0 modes for grooved defects. For plates with circular defects, the amplitude distributions did not agree well with the thickness distribution due to the refraction around the defects, defect images were seen in both modes. Especially in the amplitude distribution of S0 mode, the defect images for the circular defect were clearly obtained. [doi:10.2320/matertrans.I-M2012801]
منابع مشابه
Tissue blood flow measurement by laser Doppler technique
Measurement of blood flow and the effects of different factors on tissue blood flow are important fields of research in physiology and pharmacology. So far, different methods have been innovated, using laser light is the Last one. In this article history, principles and specifications of laser technique along with its advantages and disadvantages ( in comparison with other methods) are revie...
متن کاملRemote imaging of plate-like structures with E-camera
Thin walled large structures are widely used for pipes, bridges, wings and body of aircrafts, and automobile bodies. To maintain such large structures, in addition to visual inspection, non-destructive testing with X-ray and ultrasonic is periodically implemented for essential parts. In ultrasonic non-destructive testing, ultrasonic pulse echo technique is generally used, in which plate thickne...
متن کاملMeasurement of Electron Sheath Thickness and Collection Region of Electric Probe using Laser Photodetachment Signals
A new type of laser photodetachment (LPD) technique has been developed for the measurement of electron sheath thickness around an electrostatic probe and for the measurement of the length of collection region of photodetached electrons (PDE). When a thickness of the sheath formed around an electrostatic probe is thicker than about 0.1 mm, modification of the temporal evolution of the LPD signal...
متن کاملThickness measurement of transparent plates by a self-mixing interferometer.
We introduce a technique to measure transparent glass slab thickness. It employs a very simple setup combining two interferometers: a forward-going beam scheme and a self-mixing readout of the beam reflected back to the laser source. Interestingly, the difference of the two readouts provides a quantity related to thickness measurement, irrespective of refractive index. We demonstrate this metho...
متن کاملAltitude measurement using laser beam reflected from water surface
In this paper altitude measurement from water surface using laser beam is presented. Research data indicate that the reflection of infrared waves from water surface is about zero and it is less than 2% for visible radiations. Phase-shift and heterodyne technique was used for the measurement, and the laser beam ( mW p nm 10 , 700 = = l ) was modulated by a sine wave having a fixed frequency....
متن کامل