BACKGROUND The first Lippes Loop intrauterine device (IUD) was introduced in 1962. It was a plastic double "S" loop, a trapezoid shaped IUD that closely fit around the contours of the uterine cavity, reducing the incidence of expulsion. This IUD was commonly used from the 1960's to the 1980's. Some authors state that the IUD can be left in the uterine cavity for an indefinite amount of time. Prolonged use of this device was common, however, it was associated with some complications like uterine bleeding during post-menopausal period and inflammatory pelvic diseases. CASE PRESENTATION The patient was a 74-years-old woman who was admitted to a university hospital due to urinary incontinence stress. The patient's history included 2 deliveries and 20 years of menopause. During ultrasonography a normally sized and shaped uterus was found. The uterine cavity was expanded by 14 mm with some fluid. A "Lippes" loop was also seen in the uterine cavity. Both ovaries were atrophic without any abnormalities. The patient had her IUD inserted 50 years ago. Patient underwent TOT (tension obturator tape ) surgery for urinary incontinence. Evacuation of IUD and uterine curettage was also done. CONCLUSIONS Fifty years of prolonged usage of LIPPES IUD had no influence on the woman's health during our case.
منابع مشابه
Laparoscopic retrieval of perforated intrauterine device.
We present a case of successful laparoscopic retrieval of a perforated intrauterine device (Lippes loop). The Lippes loop was inserted after manual intrauterine adhesiolysis as a treatment of uterine synaechia presenting as secondary amenorrhoea of 20 months duration. The uterine perforation in this patient did not occur at the time of insertion but possibly during the attempt at transcervical ...
متن کاملThe Role of Three Dimensional Transvaginal Ultrasound in Detection of Intrauterine Device Displacement in Post Caesarean Section: A Case Report
Intrauterine Devices (IUDs) are used as an efficient and inexpensive method of contracep¬tion. Contraceptive efficacy depends on the intrauterine location of IUD and intrauterine displacement of the IUD leads to decreased contraceptive efficacy. Expulsion of IUD and its penetration into myometrium is one of the complications of IUD. In cases where IUDs are not detected by ultrasound method, in ...
متن کاملIntrauterine Fetal Death (IUFD) in Extra Uterus and Subsequent Pregnancy in Main Uterus: A Case Report
Abortion in an attached rndimentary uterine horn, followed by a normal intrauterine pregnancy. Pregnancy in an rudimentary uterus has been occured in many forms, and up to now about 350 cases have been reported in medical journals. Most of these malformations accompanied with other malformations in urinary tract. A case of pregnancy and abortion in an attached rudimentary uterine horn is ...
متن کاملImmediate postpartum insertion of a sutured Lippes Loop.
Use of the sutured Lippes Loop for immediate postpartum insertion was evaluated in 100 volunteers at the Kasr-el-Aini Hospital in Cairo. The intrauterine devices were inserted manually immediately after delivery of the placenta. There was an expulsion rate of 1.2 per 100 women at three months, one case of infection requiring treatment and one removal because of bleeding. One woman became pregna...
متن کاملSpontaneous Lippes Loop IUCD Intravesical Migration with Formation of Bladder Calculus and Vesicovaginal Fistula: A Case Report
Submit Manuscript | http://medcraveonline.com Spontaneous expulsions are rare, but can occur in the first months of usage, especially when the IUD is inserted shortly after childbirth. Uterine perforation is an extremely rare complication with a rate of 0.4/1000 insertions [1]. Perforation can occur during the insertion of IUD so it is recommended to be performed by an experienced gynaecologist...