Evaluation of a portable device based on peripheral arterial tone for unattended home sleep studies.

نویسندگان

  • Amir Bar
  • Giora Pillar
  • Itsik Dvir
  • Jacob Sheffy
  • Robert P Schnall
  • Peretz Lavie
چکیده

BACKGROUND Diagnosis of obstructive sleep apnea syndrome (OSAS) by ambulatory systems is a growing practice in view of the large number of patients awaiting correct diagnosis. The Watch PAT100 (WP100) [Itamar Medical; Caesarea, Israel] is a portable device based on the peripheral arterial tone (PAT) signal, and is designed for unattended home sleep studies. OBJECTIVES To evaluate the efficacy, reliability, and reproducibility of the WP100 device for the diagnosis of OSAS as compared to in-laboratory, standard polysomnographic-based manual scoring. DESIGN AND METHODS One hundred two subjects (78 men; 69 patients with OSAS and 33 normal volunteers; mean +/- SD age, 41.4 +/- 15.2 years; body mass index, 26.8 +/- 5.5) underwent in-laboratory full polysomnography simultaneously with WP100 recording. Fourteen subjects also underwent two additional unattended home sleep studies with the WP100 alone. The polysomnography recordings were blindly scored for apnea/hypopnea according to the American Academy of Sleep Medicine criteria (1999), and the polysomnography respiratory disturbance index (RDI) [PSG-RDI] was calculated. The WP100 data were analyzed automatically for the PAT RDI (PRDI) by a proprietary algorithm that was previously developed on an independent group of subjects. RESULTS Across a wide range of RDI levels, the PRDI was highly correlated with the PSG-RDI (r = 0.88, p < 0.0001), with an area under the receiver operating characteristic curve of 0.82 and 0.87 for thresholds of 10 events per hour and 20 events per hour, respectively. The PRDI scores were also highly reproducible, showing high correlation between home and in-laboratory sleep studies (r = 0.89, p < 0.001). CONCLUSION The WP100 may offer an accurate, robust, and reliable ambulatory method for the detection of OSAS, with minimal patient discomfort.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation a portable monitoring device for sleep apnea diagnosis in a population based cohort using synchronized home polysomnography.

SUBJECT OBJECTIVE To assess the accuracy of a portable monitoring device based on peripheral arterial tonometry to diagnose obstructive sleep apnea (OSA). To propose a new standard for limited-channel device validation using synchronized polysomnography (PSG) home recordings and a population-based cohort. DESIGN Single-night, unattended PSG and Watch_PAT 100 (WP_100). SETTING Home environme...

متن کامل

Home unattended portable monitoring and automatic CPAP titration in patients with high risk for moderate to severe obstructive sleep apnea.

BACKGROUND Obstructive sleep apnea is a disorder characterized by recurrent obstruction of the upper airways during sleep. The high prevalence of this disease led to proposed new strategies based on the home evaluation and management of patients. OBJECTIVE To compare home unattended portable monitoring and automatic CPAP titration with attended in-laboratory analysis, in a sample of patients ...

متن کامل

Differentiating between light and deep sleep stages using an ambulatory device based on peripheral arterial tonometry.

The objective of this study is to develop and assess an automatic algorithm based on the peripheral arterial tone (PAT) signal to differentiate between light and deep sleep stages. The PAT signal is a measure of the pulsatile arterial volume changes at the finger tip reflecting sympathetic tone variations and is recorded by an ambulatory unattended device, the Watch-PAT100, which has been shown...

متن کامل

CPT 2010: ring in the new decade with these new codes.

Let’s start with some good news: Getting paid for services that have traditionally required complex or expensive equipment or are most often provided by subspecialists should be easier with the introduction of new and revised codes for reporting these services. However, the good news comes with a caution: These codes reflect a significant change in health care delivery and, as such, payment for...

متن کامل

Portable computerized polysomnography in attended and unattended settings.

STUDY OBJECTIVE We compared the validity of a new portable polysomnographic recorder against a laboratory-based polysomnographic system from the same manufacturer. DESIGN AND PATIENTS Simultaneous, full polysomnographic recordings from the portable device (PSGP) and the laboratory-based system (PSGL) were obtained using separate sets of sensors on 20 patients referred for investigation of sle...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 123 3  شماره 

صفحات  -

تاریخ انتشار 2003