Multinational evaluation of the interpretability of the iterative method of optimisation of AV delay for CRT.
نویسندگان
چکیده
BACKGROUND AV delay optimisation of biventricular pacing devices (cardiac resynchronisation therapy, CRT) is performed in trials and recommended by current guidelines. The Doppler echocardiographic iterative method is the most commonly recommended. Yet whether it can be executed reliably has never been tested formally. METHODS 36 multinational specialists, familiar with using the echocardiographic iterative method of CRT optimisation, were shown 20-40 sets of transmitral Doppler traces at 6-8 AV settings and asked to select the optimal AV delay. Unknown to the specialists, some Doppler datasets appeared in duplicate, allowing assessment of both inter and intra-specialist interpretation. RESULTS On the Kappa scale of agreement (1 = perfect agreement, 0 = chance alone), the agreement regarding optimal AV delay between specialists was poor (kappa=0.12 ± 0.08). More importantly, agreement of specialists with themselves (i.e. viewing identical sets of traces, twice) was also poor, with Kappa=0.23 ± 0.07 and mean absolute difference in optimum AV delay of 83 ms between first and second viewing of the same traces. CONCLUSION Iterative AV optimisation is not executed reliably by experts, even in an artificially simplified context where biological variability and variation in image acquisition are eliminated by use of identical traces. This cannot be blamed on insufficient skills of some experts or discordant methods of selecting the optimum, because operators also showed poor agreement with themselves when assessing the same trace. Instead, guidelines should retract any recommendation for this algorithm. Guideline-development processes might usefully begin with a rudimentary check on proposed algorithms, to establish at least minimal credibility.
منابع مشابه
Optimisation of cardiac resynchronization therapy in clinical practice during exercise
AIMS Although cardiac resynchronisation therapy (CRT) is an established treatment to improve cardiac function, a significant amount of patients do not experience noticeable improvement in their cardiac function. Optimal timing of the delay between atrial and ventricular pacing pulses (AV delay) is of major importance for effective CRT treatment and this optimum may differ between resting and ex...
متن کاملOptimisation of cardiac resynchronisation therapy during exercise
The benefits of cardiac resynchronisation therapy (CRT) in selected cohorts with systolic dysfunction and congestive heart failure are well established [1–3]. CRT reduces heart failure hospitalisations, decreases mortality, and improves the quality of life and cardiac function, described as left ventric-ular (LV) reverse remodelling. CRT improves inter-, intra-and atrio-ventricular dyssynchrony...
متن کاملAn Improved RNS Reverse Converter in Three-Moduli Set
Residue Number System (RNS) is a carry-free and non-weighed integer system. In this paper an improved three-moduli set in reverse converter based on CRT algorithm is proposed. CRT algorithm can perform a better delay and hardware implementation in modules via other algorithms. This moduli is based on p that covers a wide range on modules and supports the whole range of its modules in dynamic r...
متن کاملDosimetric and Radiobiological Evaluation of Multiparametric MRI-guided Dose Painting in radiotherapy of Prostate Cancer
Introduction: Radiotherapy is one of the treatment options for locally advanced prostate cancer, however with standard radiation doses it is not always very effective. One of the strategies to improve the efficiency of radiotherapy is increasing the dose. In this study to increase tumor local control rates a new radiotherapy method, known as dose painting (DP) was investigated....
متن کاملHigh order quadrature based iterative method for approximating the solution of nonlinear equations
In this paper, weight function and composition technique is utilized to speeds up the convergence order and increase the efficiency of an existing quadrature based iterative method. This results in the proposition of its improved form from a two-point quadrature based method of convergence order ρ = 3 with efficiency index EI = 1:3161 to a three-point method of convergence order ρ = 8 with EI =...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of cardiology
دوره 168 1 شماره
صفحات -
تاریخ انتشار 2013