Treatment planning and evaluation of gated radiotherapy in left-sided breast cancer patients using the CatalystTM/SentinelTM system for deep inspiration breath-hold (DIBH)

نویسندگان

  • S. Schönecker
  • F. Walter
  • P. Freislederer
  • C. Marisch
  • H. Scheithauer
  • N. Harbeck
  • S. Corradini
  • C. Belka
چکیده

BACKGROUND There is a potential for adverse cardiovascular effects in long-term breast cancer survivors following adjuvant radiotherapy (RT). For this purpose, the deep inspiration breath-hold technique (DIBH) has been introduced into clinical practice, to maximally reduce the radiation dose to the heart. However, there are a variety of DIBH delivery techniques, patient positioning and visual patient feedback mechanisms. The aim of the present study was to evaluate the application of radiotherapy in DIBH using the CatalystTM/SentinelTM system, with a special emphasis on treatment planning and dosimetric plan comparison in free breathing (FB) and DIBH. PATIENTS AND METHODS A total of 13 patients with left-sided breast cancer following breast conserving surgery were included in this prospective clinical trial. For treatment application the CatalystTM/SentinelTM system (C-RAD AB, Uppsala, Sweden) was used and gating control was performed by an audio-visual patient feedback system. CT and surface data were acquired in FB and DIBH and dual treatment plans were created using Pencil Beam and Collapsed Cone Convolution. Dosimetric output parameters of organs at risk were compared using Wilcoxon signed-rank test. Central lung distance (CLD) was retrieved from iViewTM portal images during treatment delivery. RESULTS The system contains a laser surface scanner (SentinelTM) and an optical surface scanner (CatalystTM) interconnected to the LINAC systems via a gating interface and allows for a continuous and touchless surface scanning. Overall, 225 treatment fractions with audio-visual guidance were completed without any substantial difficulties. Following initial patient training and treatment setup, radiotherapy in DIBH with the CatalystTM/SentinelTM system was time-efficient and reliable. Following dual treatment planning for all patients, nine of 13 patients were treated in DIBH. In these patients, the reduction of the mean heart dose for DIBH compared to FB was 52 % (2.73 to 1.31 Gy; p = 0.011). The maximum doses to the heart and LAD were reduced by 59 % (47.90 to 19.74 Gy; p = 0.008) and 75 % (38.55 to 9.66 Gy; p = 0.008), respectively. In six of the nine patients the heart completely moved out of the treatment field by DIBH. The standard deviation of the CLD varied between 0.12 and 0.29 cm (mean: 0.16 cm). CONCLUSION The CatalystTM/SentinelTM system enabled a fast and reliable application and surveillance of DIBH in daily clinical routine. Furthermore, the present data show that using the DIBH technique during RT could significantly reduce high dose areas and mean doses to the heart. TRIAL REGISTRATION DRKS: DRKS00010929 registered on 5. August 2016.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Study of 3-D Conformal Radiotherapy Treatment Plans with and Without Deep Inspiration Breath-Hold Technique for Left-Sided Breast Cancer

Introduction: The rate of cardiac diseases have increased among patients who underwent radiotherapy for left-sided breast cancer. The study’s aim was evaluate the dose to organs at risk in free-breathing 3-dimensional conformal (FB-3DCRT) against 3-dimensional conformal deep inspiration breath-hold (3DCRT-DIBH) in patients with left-sided breast cancer. Ma...

متن کامل

Challenges of maintaining breath-hold conformity for breast patients while using the deep inspiration breath-hold technique

Deep inspiration breath-hold (DIBH) is used for whole breast radiotherapy, as a means of providing better dose homogeneity. This can be achieved by lower doses to the organs at risk, less patient movement and better set up. Most patients offered DIBH treatment are left-sided breast cancer, or ductal carcinoma in situ (DCIS) patients, due to the proximity of the heart to the chest wall so it is ...

متن کامل

Monitoring deep inspiration breath hold for left‐sided localized breast cancer radiotherapy with an in‐house developed laser distance meter system

Deep inspiration breath hold (DIBH) in left-sided breast cancer radiotherapy is a technique to reduce cardiac and pulmonary doses while maintaining target coverage. This study aims at evaluating an in-house developed DIBH system. Free-breathing (FB) and DIBH plans were generated for 22 left-sided localized breast cancer patients who had radiation therapy (RT) after breast-conserving surgery. Al...

متن کامل

Cardiac dose reduction with breathing adapted radiotherapy using self respiration monitoring system for left-sided breast cancer

PURPOSE To quantify the cardiac dose reduction during breathing adapted radiotherapy using Real-time Position Management (RPM) system in the treatment of left-sided breast cancer. MATERIALS AND METHODS Twenty-two patients with left-sided breast cancer underwent CT scans during breathing maneuvers including free breathing (FB), deep inspiration breath-hold (DIBH), and end inspiration breath-ho...

متن کامل

Improving Intra-Fractional Target Position Accuracy Using a 3D Surface Surrogate for Left Breast Irradiation Using the Respiratory-Gated Deep-Inspiration Breath-Hold Technique

PURPOSE To evaluate the use of 3D optical surface imaging as a surrogate for respiratory gated deep-inspiration breath-hold (DIBH) for left breast irradiation. MATERIAL AND METHODS Patients with left-sided breast cancer treated with lumpectomy or mastectomy were selected as candidates for DIBH treatment for their external beam radiation therapy. Treatment plans were created on both free breat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016