Comparison of continuous non-invasive finger arterial pressure monitoring with conventional intermittent automated arm arterial pressure measurement in patients under general anaesthesia.

نویسندگان

  • J J Vos
  • M Poterman
  • E A Q Mooyaart
  • M Weening
  • M M R F Struys
  • T W L Scheeren
  • A F Kalmar
چکیده

BACKGROUND For a majority of patients undergoing anaesthesia for general surgery, mean arterial pressure (MAP) is only measured intermittently by arm cuff oscillometry (MAPiNIAP). In contrast, the Nexfin(®) device provides continuous non-invasive measurement of MAP (MAPcNIAP) using a finger cuff. We explored the agreement of MAPcNIAP and MAPiNIAP with the gold standard: continuous invasive MAP measurement by placement of a radial artery catheter (MAPinvasive). METHODS In a total of 120 patients undergoing elective general surgery and clinically requiring MAPinvasive measurement, MAPiNIAP and MAPcNIAP were measured in a 30 min time period at an arbitrary moment during surgery with stable haemodynamics. MAPiNIAP was measured every 5 min. RESULTS Data from 112 patients were analysed. Compared with MAPinvasive, modified Bland-Altman analysis revealed a bias (sd) of 2 (9) mm Hg for MAPcNIAP and -2 (12) mm Hg for MAPiNIAP. Percentage errors for MAPcNIAP and MAPiNIAP were 22% and 32%, respectively. CONCLUSIONS In a haemodynamically stable phase in patients undergoing general anaesthesia, the agreement with invasive MAP of continuous non-invasive measurement using a finger cuff was not inferior to the agreement of intermittent arm cuff oscillometry. Continuous measurements using a finger cuff can interchangeably be used as an alternative for intermittent arm cuff oscillometry in haemodynamically stable patients, with the advantage of beat-to-beat haemodynamic monitoring. CLINICAL TRIAL REGISTRATION NCT 01362335 (clinicaltrials.gov).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study

Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...

متن کامل

Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement.

BACKGROUND Arterial pressure (AP) monitoring should be accurate, easy to use, free of risks, and ideally continuous. The continuous non-invasive arterial pressure (CNAP) device is non-invasive and provides continuous pressure readings. This study was performed to compare the agreement of CNAP and invasive AP monitoring. METHODS Ninety patients undergoing surgery under general anaesthesia were...

متن کامل

Radial artery tonometry: moderately accurate but unpredictable technique of continuous non-invasive arterial pressure measurement.

Radial artery tonometry provides continuous measurement of non-invasive arterial pressure (CNAP) by a sensor positioned above the radial artery. An inflatable upper arm cuff enables intermittent oscillometric calibration. CNAP was compared with invasive radial artery pressure recordings from the opposite wrist in 22 high-risk surgical patients with an inter-arm oscillometric mean arterial press...

متن کامل

Techniques for Non-Invasive Monitoring of Arterial Blood Pressure

Since both, hypotension and hypertension, can potentially impair the function of vital organs such as heart, brain, or kidneys, monitoring of arterial blood pressure (BP) is a mainstay of hemodynamic monitoring in acutely or critically ill patients. Arterial BP can either be obtained invasively via an arterial catheter or non-invasively. Non-invasive BP measurement provides either intermittent ...

متن کامل

Continuous Non-invasive Arterial Pressure Device as an Adjunct to Recognize Fluctuating Blood Pressures during Elective Cesarean Section under Subarachnoid Blockade (sab).

BACKGROUND Measuring non-invasive blood pressure (NIBP) in less than one minute intervals (STAT NIBP measurements) is not always feasible. Therefore, large number of undetectable hypotension episodes can only be recognized with continuous beat to beat monitoring of blood pressure, for example, by continuous non-invasive arterial pressure monitor (CNAP). OBJECTIVE The purpose of the current st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 113 1  شماره 

صفحات  -

تاریخ انتشار 2014