Odour Regulation in Germany – an improved system including odour intensity, hedonic tone and odour annoyance
نویسندگان
چکیده
For odour regulation in Germany the Guideline on Odour in ambient Air GOAA has been in use for many years. The main parameter the odour regulation authority has to take into account is the odour frequency expressed as odour hours per year. In the Guideline limit values are given for the maximum odour frequency per year. These limit values are based on investigations in the field in which significant relationships between odour impact and odour annoyance were found. In these investigations odour intensity did not yield a better description of the annoyance degree of residents. The hedonic tone was not mentioned. In a new research project the influence of odour intensity and hedonic tone in addition to odour frequency has been assessed. As a consequence of this investigation there is no need to modify the fundamental system of data acquisition, analysis and evaluation of the GOAA but the results show that in some cases (pleasant odours) it is necessary to include hedonic tone. Therefore hedonic tone in the case of pleasant odours and a reliable and valid method to evaluate hedonic tone in the field is included in the GOAA.
منابع مشابه
Odour intensity and hedonic tone--important parameters to describe odour annoyance to residents?
The Guideline on Odour in Ambient Air has been in use for many years for odour regulation in Germany. The main parameter that the odour regulation authority has to take into account is the odour frequency expressed as odour hours per year. In the guideline, limit values are given for the maximum odour frequency per year. These limit values are based on field investigations in which significant ...
متن کاملDetermination of Odour Interactions of Three-Component Gas Mixtures Using an Electronic Nose
The paper presents an application of an electronic nose prototype comprised of six TGS-type sensors and one PID-type sensor to identify odour interaction phenomena in odorous three-component mixtures. The investigation encompassed eight odorous mixtures-toluene-acetone-triethylamine and formaldehyde-butyric acid-pinene-characterized by different odour intensity and hedonic tone. A principal com...
متن کاملDetermination of Odour Interactions in Gaseous Mixtures Using Electronic Nose Methods with Artificial Neural Networks
This paper presents application of an electronic nose prototype comprised of eight sensors, five TGS-type sensors, two electrochemical sensors and one PID-type sensor, to identify odour interaction phenomenon in two-, three-, four- and five-component odorous mixtures. Typical chemical compounds, such as toluene, acetone, triethylamine, α-pinene and n-butanol, present near municipal landfills an...
متن کاملPotential of a Network of Electronic Noses to Assess in Real Time the Odour Annoyance in the Environment of a Compost Facility
This paper presents a complete approach of continuous odour monitoring around an industrial plant, with an e-nose network named FIDOR, providing in real time the five components of the odour annoyance, the frequency, the intensity, the duration, the offensiveness and the impact on the receptor. Such FIDOR network was placed in the immediate surroundings of a compost facility in Belgium. Results...
متن کاملDetermining tolerance to odour annoyance in communities near hog operations
La, A., Q. Zhang and Z. Gao. 2014. Determining tolerance to odour annoyance in communities near hog operations. Canadian Biosystems Engineering/Le génie des biosystèmes au Canada 56: 6.1-6.11. Quantifying the impact of odour from livestock facilities has been a challenge to researchers and environmental regulators. Physical and sensory odour attributes are commonly used to define the odour impa...
متن کامل