Rapid solubility test for detection of hemoglobin S.

نویسندگان

  • J E Matusik
  • J B Powell
  • D M Gregory
چکیده

Several screening methods for detecting sickling hemoglobins are presently used in the clinical laboratory (1-6). The present procedure depends on the insolubility of reduced hemoglobin S in a 2.24 mol/liter phosphate buffer. The commercially available “Sickledex” (Ortho Diagnostics, Raritan, N.J. 08869) is also thought to be based on this principle (6). Our method was compared with the standard sodium metabisulfite procedure and with the Sickledex test. In addition, results of the screening methods were verified by electrophoresis. This report presents a reliable, sensitive, and inexpensive means of detecting hemoglobin S and other sickling hemoglobins. A turbidimetric test, it is performed similarly to the Sickledex test.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Polymerase chain reaction for the detection and differentiation of Marek’s disease virus strains MDV-1 and HVT

Marek’s disease (MD) is a lymphoproliferative disease of chickens characterized by lymphocyticinfiltration of various organs. The present study was an attempt to use polymerase chain reaction (PCR) tooptimize a rapid and reliable assay for detection of MDV genome. Detection of serotype 1 of MDV (MDV-1)was confirmed by presence of a 200 bp DNA fragment as a PCR product. Differentiation of MDV-1 ...

متن کامل

A rapid whole blood solubility test to differentiate the sickle-cell trait from sickle-cell anaemia.

A simple and rapid screening test which differentiates sickle-cell trait and sickle-cell anaemia is described. The test utilizes 0.1 ml of whole blood and is based on the low solubility of reduced sickle haemoglobin. Results intermediate between the sickle-cell trait and sickle-cell anaemia are obtained in unusual cases of sickle-cell anaemia with high foetal haemoglobin. The need to supplement...

متن کامل

Detection of Infectious Bronchitis Virus in Allantioc Fluid by Rapid Hemagglutination Test.

To detect the presence of infectious bronchitis virus (IBV) in infected allantoic fluid (AF) of SPF embryonated eggs rapid hemagglutination (HA) activity after treatment with neuraminidase enzyme was used. Twenty IBV suspected materials were inoculated in SPF embryonated eggs via chorioallantoic cavity. Harvested AFs were treated with neuraminidase enzyme and the presence of IBV was detected by...

متن کامل

A modification of the "Sickledex" test for hemoglobin S.

The “Sickledex” test (as described by Diggs et al., in a scientific exhibit, 1968, and marketed by Ortho Diagnostics, Raritan, N. J. 08869) has gained widespread use as a screening method for hemoglobin S (1, 2). Apparently based on the solubility test of Itano (3), it has been shown to be positive with abnormal hemoglobins other than the S hemoglobin (4). Nevertheless, it is a quick, simple sc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 17 11  شماره 

صفحات  -

تاریخ انتشار 1971