A respiratory training system based on audiovisual biofeedback has been implemented at our institution. It is intended to improve patients' respiratory regularity during four-dimensional (4D) computed tomography (CT) image acquisition. The purpose is to help eliminate the artifacts in 4D-CT images caused by irregular breathing, as well as improve delivery efficiency during treatment, where respiratory irregularity is a concern. This article describes the commissioning and quality assurance (QA) procedures developed for this peripheral respiratory training system, the Stanford Respiratory Training (START) system. Using the Varian real-time position management system for the respiratory signal input, the START software was commissioned and able to acquire sample respiratory traces, create a patient-specific guiding waveform, and generate audiovisual signals for improving respiratory regularity. Routine QA tests that include hardware maintenance, visual guiding-waveform creation, auditory sounds synchronization, and feedback assessment, have been developed for the START system. The QA procedures developed here for the START system could be easily adapted to other respiratory training systems based on audiovisual biofeedback.
منابع مشابه
WE-G-213CD-07: Enhancing Respiratory Motion Prediction Accuracy Using Audiovisual (AV) Biofeedback.
PURPOSE Prediction of respiratory-related tumor motion is hampered by irregularities present in the patient breathing patterns. Audiovisual (AV) biofeedback reduces irregularities, thereby producing a less complex breathing pattern. The aim of this project is to improve respiratory motion prediction accuracy using an AV biofeedback system. METHODS An AV biofeedback system combined with real-t...
متن کاملAudiovisual biofeedback improves image quality and reduces scan time for respiratory-gated 3D MRI
The purpose of this study was to test the hypothesis that audiovisual (AV) biofeedback can improve image quality and reduce scan time for respiratory-gated 3D thoracic MRI. For five healthy human subjects respiratory motion guidance in MR scans was provided using an AV biofeedback system, utilizing real-time respiratory motion signals. To investigate the improvement of respiratory‐gated 3D MR i...
متن کاملAudiovisual Biofeedback-Based Trunk Stabilization Training Using a Pressure Biofeedback System in Stroke Patients: A Randomized, Single-Blinded Study
The purpose of this study was to assess the effects of audiovisual biofeedback-based trunk stabilization training using a pressure biofeedback system (PBS) in stroke patients. Forty-three chronic stroke patients, who had experienced a stroke more than 6 months ago and were able to sit and walk independently, participated in this study. The subjects were randomly allocated to an experimental gro...
متن کاملA Specific Patient Quality Assurance (PSQA) procedure for a Co-60 source based High Dose Rate Brachytherapy
Introduction: In radiation therapy, accurate dose determination and precise dose delivery to the tumor are directly associated with better treatment outcomes in terms of higher tumor control and lower post radiation therapy complications. The current study aims the development and clinical application of the Patient Specific Quality Assurance (PSQA) procedures for nasopharyngea...
متن کاملComparison between audio-only and audiovisual biofeedback for regulating patients' respiration during four-dimensional radiotherapy
PURPOSE To compare audio-only biofeedback to conventional audiovisual biofeedback for regulating patients' respiration during four-dimensional radiotherapy, limiting damage to healthy surrounding tissues caused by organ movement. MATERIALS AND METHODS Six healthy volunteers were assisted by audiovisual or audio-only biofeedback systems to regulate their respirations. Volunteers breathed throu...
متن کامل