Repeated measurements of tibia lead concentrations by in vivo x ray fluorescence in occupational exposure.
نویسندگان
چکیده
A group of workers occupationally exposed to lead have had measurements of their tibia lead concentrations made on two occasions separated by five years; on the second occasion calcaneus lead concentrations were also measured. The results serve to confirm the reliability of the measurement technique and to illustrate the improved precision achieved through technical improvements. More importantly, the relation between tibia lead concentration and cumulative blood lead found in this longitudinal study was entirely consistent with that previously reported, which had been based on cross sectional studies. Furthermore, the relation between lead concentrations in the tibia and in calcaneus found here was similar to that previously found in a larger cross sectional survey. It is concluded that this technique of measuring bone lead concentrations non-invasively is likely to be used increasingly as a biological monitor of cumulative exposure to lead.
منابع مشابه
Impact of Occupational Exposure on Lead Levels in Women
In 1994, 207 women participated in a study designed to examine the effects of occupational exposure and various lifestyle factors on bone and blood lead levels. In vivo measurements of Pb concentrations in tibia were performed by X-ray fluorescence. All 108 former smelter employees and 99 referents provided blood samples and answered a questionnaire on lifestyle characteristics and the relevant...
متن کاملIn vivo measurements of lead in bone at four anatomical sites: long term occupational and consequent endogenous exposure.
Measurements of bone lead concentrations in the tibia, wrist, sternum, and calcaneus were performed in vivo by x ray fluorescence on active and retired lead workers from two acid battery factories, office personnel in the two factories under study, and control subjects. Altogether 171 persons were included. Lead concentrations in the tibia and ulna (representative of cortical bone) appeared to ...
متن کامل109Cd K x ray fluorescence measurements of tibial lead content in young adults exposed to lead in early childhood.
OBJECTIVES Tibia lead measurements were performed in a population of 19-29 year old people who had been highly exposed to lead in childhood to find whether lead had persisted in the bone matrix until adulthood. METHODS (109)Cd K x ray fluorescence was used to measure the tibia lead concentrations of 262 exposed subjects and 268 age and sex matched controls. Questionnaire data allowed a years ...
متن کاملIn vivo tibia lead measurements as an index of cumulative exposure in occupationally exposed subjects.
In vivo tibia lead measurements of 20 non-occupationally exposed and 190 occupationally exposed people drawn from three factories were made using a non-invasive x ray fluorescence technique in which characteristic x rays from lead are excited by gamma rays from a cadmium-109 source. The maximum skin dose to a small region of the shin was 0.45 mSv. The relation between tibia lead and blood lead ...
متن کاملEffects of low level exposure to lead on neurophysiological functions among lead battery workers.
OBJECTIVES Assessment of neurophysiological functions in workers with low level exposure to lead and evaluation of the efficacy of bone lead measurements in the prediction of effects of lead. METHODS Exposure to lead of 60 workers from a lead battery battery factory was estimated from historical blood lead measurements and analysis of lead in the tibial and calcaneal bones with x ray fluoresc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of industrial medicine
دوره 49 1 شماره
صفحات -
تاریخ انتشار 1992