System accuracy evaluation of 27 blood glucose monitoring systems according to DIN EN ISO 15197.

نویسندگان

  • Guido Freckmann
  • Annette Baumstark
  • Nina Jendrike
  • Eva Zschornack
  • Serge Kocher
  • Jacques Tshiananga
  • Frank Heister
  • Cornelia Haug
چکیده

BACKGROUND Blood glucose (BG) monitoring systems enable diabetes patients to effectively control and adjust their therapy. BG monitoring systems with a Conformité Européenne (CE) label should meet the standard DIN EN ISO 15197:2003: > or =95% of the BG results shall fall within +/-15 mg/dL of the reference method at BG concentrations <75 mg/dL and within +/-20% at BG concentrations > or =75 mg/dL. We intended to verify if BG monitoring systems with a CE label fulfill these minimum accuracy requirements. METHODS We evaluated 27 BG monitoring systems from 18 manufacturers for system accuracy according to DIN EN ISO 15197:2003. Twenty-four systems were compared with the glucose oxidase reaction (YSI 2300 glucose analyzer [YSI Life Sciences, Yellow Springs, OH]) and three systems with the hexokinase reaction (Hitachi 917 [Roche Diagnostics GmbH, Mannheim, Germany]). Duplicate measurements of 100 blood samples with a defined distribution of BG concentrations from 20 mg/dL to 600 mg/dL from > or =100 subjects were included in the evaluation. RESULTS Sixteen of the 27 BG monitoring systems fulfilled the minimum accuracy requirements of the standard, i.e., > or =95% of their results showed the minimum acceptable accuracy. Overall, the mean percentage of results showing the minimum acceptable accuracy was 95.2 +/- 5.2%, ranging from 80.0% to 100.0%. CONCLUSIONS More than 40% of the evaluated BG monitoring systems did not fulfill the minimum accuracy requirements of DIN EN ISO 15197:2003. As inaccurate BG monitoring systems bear the risk of false treatment decisions by the diabetes patient and subsequent possible severe health injury, manufacturers should regularly and effectively check the quality of BG meters and BG test strips.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

System accuracy evaluation of 43 blood glucose monitoring systems for self-monitoring of blood glucose according to DIN EN ISO 15197.

BACKGROUND The accuracy of systems for self-monitoring of blood glucose is important, as reliable measurement results are a prerequisite for therapeutic decisions. METHODS This system accuracy evaluation study was performed according to DIN EN ISO 15197:2003 for 43 Conformité Européenne (CE)-labeled blood glucose (BG) monitoring systems. Measurement results of each system were compared with r...

متن کامل

Lot-to-lot variability of test strips and accuracy assessment of systems for self-monitoring of blood glucose according to ISO 15197.

BACKGROUND Accurate and reliable blood glucose (BG) measurements require that different test strip lots of the same BG monitoring system provide comparable measurement results. Only a small number of studies addressing this question have been published. METHODS In this study, four test strip lots for each of five different BG systems [Accu-Chek® Aviva (system A), FreeStyle Lite® (system B), G...

متن کامل

System accuracy of blood glucose monitoring devices according to the current and proposed ISO 15197 standards.

Corresponding Author: Guido Freckmann, M.D., Institut für Diabetes-Technologie Forschungsund Entwicklungsgesellschaft mbH, Helmholtzstrasse 20, 89081 Ulm, Germany; email address [email protected] In a letter to the editor, Teodorczyk and coauthors1 comment on our data2 published in Journal of Diabetes Science and Technology. In studies2 conducted at the Institut für Diabetes-Technologi...

متن کامل

Accuracy of Four Blood Glucose Monitoring Systems

Background: The minimum acceptable accuracy for results produced by a blood glucose monitoring system according to the current version of ISO 15197, created in 2003, is: 95% of the individual glucose results shall fall within ±15 mg/dL (0.83 mmol/L) of the results of the manufacturer’s measurement procedure at glucose concentrations < 75 mg/dL (< 4.2 mmol/L) and within ±20% at glucose concentra...

متن کامل

Comment on “System Accuracy Evaluation of the GlucoRx Nexus Voice TD-4280 Blood Glucose Monitoring System”

Use of blood glucose (BG) meters in the self-monitoring of blood glucose (SMBG) significantly lowers the risk of diabetic complications. With several BG meters now commercially available, the International Organization for Standardization (ISO) ensures that each BG meter conforms to a set degree of accuracy. Although adherence to ISO guidelines is a prerequisite for commercialization in Europe,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diabetes technology & therapeutics

دوره 12 3  شماره 

صفحات  -

تاریخ انتشار 2010