Validation of accuracy-based amino acid reference materials in dried-blood spots by tandem mass spectrometry for newborn screening assays.

نویسندگان

  • D H Chace
  • B W Adam
  • S J Smith
  • J R Alexander
  • S L Hillman
  • W H Hannon
چکیده

BACKGROUND Advances in technology and the earlier release of newborns from hospitals have pressed the demand for accurate calibration and improved interlaboratory performance for newborn screening tests. As a first step toward standardization of newborn screening aminoacidopathy tests, we have produced six-pool sets of multianalyte dried-blood-spot amino acid reference materials (AARMs) containing predetermined quantities of five amino acids. We describe here the production of the AARMs, validation of their amino acid contents, and characterization of their homogeneity and their stability in storage. METHODS To each of six portions of a pool of washed erythrocytes suspended in serum we added Phe (0-200 mg/L), Leu (0-200 mg/L), Met (0-125 mg/L), Tyr (0-125 mg/L), and Val (0-125 mg/L). Six-pool sets (1300) were prepared, dried, and packaged. We used isotope-dilution mass spectrometry to estimate the endogenous amino acid concentrations of the AARMs and validate their final amino acid concentrations. We used additional tandem mass spectrometry analyses to examine the homogeneity of amino acid distribution in each AARM, and HPLC analyses to evaluate the stability of the amino acid contents of the AARMs. RESULTS The absolute mean biases across the analytic range for five amino acids were 2.8-9.4%. One-way ANOVAs of the homogeneity results predicted no statistically significant differences in amino acid concentrations within the blood spots or within the pools (P >0.05). Regression slopes (0 +/- 0.01) for amino acid concentrations vs storage times and their P values (>0.05) showed no evidence of amino acid degradation at ambient temperatures, 4 degrees C, or -20 degrees C during the intervals tested. CONCLUSION The validation, homogeneity, and stability of these blood spots support their use as a candidate national reference material for calibration of assays that measure amino acids in dried-blood spots.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of turbidimetric high-sensitivity C-reactive protein assays for cardiovascular risk estimation.

tions. J Chromatogr 1992;577:205–14. 11. Matsumoto I, Kuhara T. Inborn errors of amino acid and organic acid metabolism. In: Desiderio DM, ed. Mass spectrometry: clinical and biomedical applications, Vol. I. New York: Plenum Press, 1992:259–98. 12. Chace DH. Mass spectrometry in the clinical laboratory. Chem Rev 2001; 101:445–77. 13. Millington D, Chace D. Carnitine and acylcarnitines in metabo...

متن کامل

Rapid diagnosis of homocystinuria and other hypermethioninemias from newborns' blood spots by tandem mass spectrometry.

We report a new method for the diagnosis of homocystinuria and other hypermethioninemias from dried blood spots on newborn screening cards, based on isotope-dilution tandem mass spectrometry. The mean concentration of methionine in 909 unaffected newborns was 19 micromol/L (CV 44%). The variability of results was reduced when the concentration of methionine was expressed relative to that of ano...

متن کامل

Tandem mass spectrometry for the direct assay of enzymes in dried blood spots: application to newborn screening for mucopolysaccharidosis II (Hunter disease).

BACKGROUND A treatment for mucopolysaccharidosis II (Hunter syndrome) has recently become available. Therefore, we developed a high-throughput assay method appropriate for newborn screening for the relevant enzyme, iduronate 2-sulfatase. METHODS We synthesized a new iduronate 2-sulfatase substrate that can be used to assay the enzyme by use of tandem mass spectrometry together with an interna...

متن کامل

Newborn screening for hepatorenal tyrosinemia: Tandem mass spectrometric quantification of succinylacetone.

BACKGROUND False-positive and false-negative results occur in current newborn-screening programs for hepatorenal tyrosinemia, which measure tyrosine concentrations in blood spots, sometimes in combination with other metabolites, including succinylacetone. We present our experience with a newly described method for succinylacetone quantification in routine newborn screening. METHODS Succinylac...

متن کامل

Use of tandem mass spectrometry for multianalyte screening of dried blood specimens from newborns.

BACKGROUND Over the past decade laboratories that test for metabolic disorders have introduced tandem mass spectrometry (MS/MS), which is more sensitive, specific, reliable, and comprehensive than traditional assays, into their newborn-screening programs. MS/MS is rapidly replacing these one-analysis, one-metabolite, one-disease classic screening techniques with a one-analysis, many-metabolites...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 45 8 Pt 1  شماره 

صفحات  -

تاریخ انتشار 1999