Dose-volume relationships associated with temporal lobe radiation necrosis after skull base proton beam therapy.
نویسندگان
چکیده
PURPOSE We evaluated patient and treatment parameters correlated with development of temporal lobe radiation necrosis. METHODS AND MATERIALS This was a retrospective analysis of a cohort of 66 patients treated for skull base chordoma, chondrosarcoma, adenoid cystic carcinoma, or sinonasal malignancies between 2005 and 2012, who had at least 6 months of clinical and radiographic follow-up. The median radiation dose was 75.6 Gy (relative biological effectiveness [RBE]). Analyzed factors included gender, age, hypertension, diabetes, smoking status, use of chemotherapy, and the absolute dose:volume data for both the right and left temporal lobes, considered separately. A generalized estimating equation (GEE) regression analysis evaluated potential predictors of radiation necrosis, and the median effective concentration (EC50) model estimated dose-volume parameters associated with radiation necrosis. RESULTS Median follow-up time was 31 months (range 6-96 months) and was 34 months in patients who were alive. The Kaplan-Meier estimate of overall survival at 3 years was 84.9%. The 3-year estimate of any grade temporal lobe radiation necrosis was 12.4%, and for grade 2 or higher radiation necrosis was 5.7%. On multivariate GEE, only dose-volume relationships were associated with the risk of radiation necrosis. In the EC50 model, all dose levels from 10 to 70 Gy (RBE) were highly correlated with radiation necrosis, with a 15% 3-year risk of any-grade temporal lobe radiation necrosis when the absolute volume of a temporal lobe receiving 60 Gy (RBE) (aV60) exceeded 5.5 cm(3), or aV70 > 1.7 cm(3). CONCLUSIONS Dose-volume parameters are highly correlated with the risk of developing temporal lobe radiation necrosis. In this study the risk of radiation necrosis increased sharply when the temporal lobe aV60 exceeded 5.5 cm(3) or aV70 > 1.7 cm(3). Treatment planning goals should include constraints on the volume of temporal lobes receiving higher dose. The EC50 model provides suggested dose-volume temporal lobe constraints for conventionally fractionated high-dose skull base radiation therapy.
منابع مشابه
Comparison of three different techniques in parotid gland tumors using three dimensional conformal radiation therapy
Introduction: Background: Radiotherapy of parotid tumors is achieved by different radiotherapy techniques. So they deliver the dose to organs at risk such as contralateral parotid, temporal lobe & spinal cord. The consequences of high dose to OARs are xerostomia, Temporal lobe necrosis and loss of hearing. Purpose: The aim of this study was to compare different treatment tech...
متن کاملFeasibility of proton beam therapy for chordoma and chondrosarcoma of the skull base.
We explored the general feasibility of proton beam therapy for chordoma and chondrosarcoma of the skull base. Clinical records and treatment-planning data of patients with the pathological diagnosis of chordoma or chondrosarcoma were examined. Proton beam therapy was administered for gross tumor mass as well as microscopic residual disease after surgery. The prescribed dose was determined to ma...
متن کاملRadiologic patterns of necrosis after proton therapy of skull base tumors.
BACKGROUND Discrimination between radiation necrosis and tumor progression after radiation therapy represents a radiologic challenge. The aim of our investigation is to identify patterns of radiation necrosis on brain magnetic resonance imaging (MRI) and positron emission tomography (PET) with Fluoroethyltyrosin (FET) after proton beam therapy (PBT) for skull base tumors. MATERIAL AND METHODS...
متن کاملComparison of intensity modulated radiotherapy (IMRT) with intensity modulated particle therapy (IMPT) using fixed beams or an ion gantry for the treatment of patients with skull base meningiomas
BACKGROUND To examine the potential improvement in treatment planning for patients with skull base meningioma using IMRT compared to carbon ion or proton beams with and without a gantry. METHODS Five patients originally treated with photon IMRT were selected for the study. Ion beams were chosen using a horizontal beam or an ion gantry. Intensity controlled raster scanning and the intensity mo...
متن کاملInvestigation of tumor motion influence on applied dose distribution in conventional proton therapy vs. IMPT a 4D Monte Carlo simulation study
Background: in radiation treatment of moving targets located in thorax region of patient body, the delivered dose does not match with the planned treatment, resulting in some over and under dosage in the tumor volume, as a function of motion magnitude and frequency. Several efforts have been done to investigate the target motion effects on dose distribution in the target and surrounding normal ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of radiation oncology, biology, physics
دوره 91 2 شماره
صفحات -
تاریخ انتشار 2015