Comparison of Simulated Workplace Protection Factors Offered by N 95 and P 100 Filtering Facepiece and Elastomeric Half - Mask Respirators

نویسندگان

  • Xinjian He
  • Evanly Vo
چکیده

This study compared the simulated workplace protection factors (SWPFs) between NIOSH-approved N95 respirators and P100 respirators, including two models of filtering facepiece respirator (FFR) and two models of elastomeric halfmask respirator (EHR),against sodium chloride particles (NaCl) in a range of 10 to 400 nm. Twenty-five human test subjects performed modified OSHA fit test exercises in a controlled laboratory environment with the N95 respirators (two FFR models and two EHR models) and the P100 respirators (two FFRs and two EHRs). Two Scanning Mobility Particle Sizers (SMPS) were used to measure aerosol concentrations (in the 10-400 nm size range) inside (Cin) and outside (Cout) of the respirator, simultaneously. SWPF was calculated as the ratio of Cout to Cin. The SWPF values obtained from the N95 respirators were then compared to those of the P100 respirators. SWPFs were found to be significantly different (P<0.05) between N95 and P100 class respirators. The 10th, 25th, 50th, 75th and 90th percentiles of the SWPFs for the N95 respirators were much lower than those for the P100 models. The N95 respirators had 5th percentiles of the SWPFs > 10. In contrast, the P100 class was able to generate 5th percentiles SWPFs > 100. No significant difference was found in the SWPFs when tested against nano-size (10 to 100 nm) and large-size (100 to 400 nm) particles. Overall, the findings suggest that the two FFRs and two EHRs with P100 class filters provide better performance than those with N95 filters against particles from 10 to 400 nm, supporting current OSHA and NIOSH recommendations. *Corresponding author: Ziqing Zhuang, NIOSH-NPPTL, 626 Cochrans Mill Road, Pittsburgh, PA 15236, USA; Tel: +1 4123864055. E-mail: [email protected]

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Simulated Workplace Protection Factors Offered by N95 and P100 Filtering Facepiece and Elastomeric Half-Mask Respirators against Particles of 10 to 400 nm

This study compared the simulated workplace protection factors (SWPFs) between NIOSH-approved N95 respirators and P100 respirators, including two models of filtering facepiece respirator (FFR) and two models of elastomeric half-mask respirator (EHR), against sodium chloride particles (NaCl) in a range of 10 to 400 nm. Twenty-five human test subjects performed modified OSHA fit test exercises in...

متن کامل

Comparison of Simulated Workplace Protection Factors Offered by N 95 and P 100

This study compared the simulated workplace protection factors (SWPFs) between NIOSH-approved N95 respirators and P100 respirators, including two models of filtering facepiece respirator (FFR) and two models of elastomeric halfmask respirator (EHR),against sodium chloride particles (NaCl) in a range of 10 to 400 nm. Twenty-five human test subjects performed modified OSHA fit test exercises in a...

متن کامل

Protection of firefighters against combustion aerosol particles: simulated workplace protection factor of a half-mask respirator (pilot study).

The present pilot study investigated the penetration of ultrafine particles originated by combustion of different materials into elastomeric half-mask respirators equipped with two P100 filters. We determined the Simulated Workplace Protection Factor (SWPF) for 11 firefighters wearing elastomeric half-mask respirators and performing activities simulating those conducted during fire overhaul ope...

متن کامل

Evaluation of a quantitative fit testing method for N95 filtering facepiece respirators.

A method for performing quantitative fit tests (QNFT) with N95 filtering facepiece respirators was developed by earlier investigators. The method employs a simple clamping device to allow the penetration of submicron aerosols through N95 filter media to be measured. The measured value is subtracted from total penetration, with the assumption that the remaining penetration represents faceseal le...

متن کامل

Particle Size-Selective Assessment of Protection of European Standard FFP Respirators and Surgical Masks against Particles-Tested with Human Subjects

This study was conducted to investigate the protection of disposable filtering half-facepiece respirators of different grades against particles between 0.093 and 1.61  μm. A personal sampling system was used to particle size-selectively assess the protection of respirators. The results show that about 10.9% of FFP2 respirators and 28.2% of FFP3 respirators demonstrate assigned protection factor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017