Metal allergy to titanium bars after the Nuss procedure for pectus excavatum.

نویسندگان

  • Kazuhiro Sakamoto
  • Kohei Ando
  • Daisuke Noma
چکیده

The Nuss procedure requires the placement of metal bars in the chest cage to repair pectus excavatum. Metal allergies are one of the complications associated with this procedure. Given that titanium is a biocompatible metal, it induces few allergic symptoms. Therefore, titanium bars are recommended for patients with metal sensitivity. We report the case of a 17-year-old boy with pectus excavatum who had a metal allergy to titanium bars, which occurred after the Nuss procedure. The administration of oral steroids is useful for treating metal allergies. Metal allergies to titanium bars are very rare; however, they can still occur.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

When it is not an infection: metal allergy after the Nuss procedure for repair of pectus excavatum.

PURPOSE Increasing use of implantable bars for minimally invasive pectus excavatum repair has introduced metal allergy (nickel and chromium) to pediatric surgeons. Metal allergy is a well-recognized entity in neurologic, orthopedic, and craniofacial surgery. This study was performed to evaluate metal allergy and its effects on treatment with the Nuss procedure in 862 patients. METHODS After i...

متن کامل

First Iranian Experience of the Minimally Invasive Nuss Procedure for Pectus Excavatum Repair: A Case Series and Literature Review

Pectus excavatum is the most common congenital deformity of the chest wall. The most frequently used techniques include Ravitch (costochondral resection) and Nuss (minimally invasive pectus repair of pectus excavatum [MIRPE]). The Nuss technique includes using temporary metallic bars without costochondral resection to correct the chest wall deformity. Modified MIRPE can be learned easily and pe...

متن کامل

New material for Nuss procedure.

The Nuss procedure for pectus excavatum repair has been considered an acceptable method in terms of its decreased invasiveness and excellent cosmetic results. Although a steel bar is usually used for elevating the sternum, we used a titanium alloy plate for pectus excavatum repair for the first time. The characteristics of this plate are that 1) it comes out translucently on X-rays, 2) MRI exam...

متن کامل

Early results following the Nuss operation for pectus excavatum--a single-institution experience of 383 patients.

The prevalence of pectus excavatum is low but many patients are disabled from this thoracic deformity. The Nuss operation is a well-established surgical correction, however, until recently it has been rarely used in Europe. We have performed the Nuss operation regularly between 2001 and 2006 where a total of 383 patients were operated on for pectus excavatum. The indication for surgery was disa...

متن کامل

Peri-operative data on the nuss procedure in children with pectus excavatum: independent survey of the first 20 years' data

OBJECTIVE To review the literature and assess the cumulative data on the Nuss operation in children on its twenty years' anniversary: The Nuss procedure corrects the pectus excavatum by minimal access semi-permanent insertion of metal bars in order to reduce the deformity and refashion the contour of the growing thorax. The advantage over previous techniques is avoidance of osteochondrotomies a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of thoracic surgery

دوره 98 2  شماره 

صفحات  -

تاریخ انتشار 2014