Respiratory weakness after mechanical ventilation is associated with one-year mortality - a prospective study

نویسندگان

  • Clément Medrinal
  • Guillaume Prieur
  • Éric Frenoy
  • Aurora Robledo Quesada
  • Antoine Poncet
  • Tristan Bonnevie
  • Francis-Edouard Gravier
  • Bouchra Lamia
  • Olivier Contal
چکیده

BACKGROUND Diaphragm dysfunction in mechanically ventilated patients is associated with poor outcome. Maximal inspiratory pressure (MIP) can be used to evaluate inspiratory muscle function. However, it is unclear whether respiratory weakness is independently associated with long-term mortality. The aim of this study was to determine if low MIP is independently associated with one-year mortality. METHODS We conducted a prospective observational cohort study in an 18-bed ICU. Adults requiring at least 24 hours of mechanical ventilation with scheduled extubation and no evidence of pre-existing muscle weakness underwent MIP evaluation just before extubation. Patients were divided into two groups: low MIP (MIP ≤30 cmH2O) and high MIP (MIP >30 cmH2O). Mortality was recorded for one year after extubation. For the survival analysis, the effect of low MIP was assessed using the log-rank test. The independent effect of low MIP on post mechanical ventilation mortality was analyzed using a multivariable Cox regression model. RESULTS One hundred and twenty-four patients underwent MIP evaluation (median age 66 years (25(th)-75(th) percentile 56-74), Simplified Acute Physiology Score (SAPS) 2 = 45 (33-57), duration of mechanical ventilation 7 days (4-10)). Fifty-four percent of patients had low MIP. One-year mortality was 31 % (95 % CI 0.21, 0.43) in the low MIP group and 7 % (95 % CI 0.02, 0.16) in the high MIP group. After adjustment for SAPS 2 score, body mass index and duration of mechanical ventilation, low MIP was independently associated with one-year mortality (hazard ratio 4.41, 95 % CI 1.5, 12.9, p = 0.007). Extubation failure was also associated with low MIP (relative risk 3.0, 95 % CI 1, -9.6; p = 0.03) but tracheostomy and ICU length of stay were not. CONCLUSION Low MIP is frequent in patients on mechanical ventilation and is an independent risk factor for long-term mortality in ICU patients requiring mechanical ventilation. MIP is easily evaluated at the patient's bedside. TRIAL REGISTRATION This study was retrospectively registered in www.clinicaltrials.gov (NCT02363231) in February 2015.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی عوارض ریوی ناشی از تهویه مکانیکی در نوزادان بستری در بخش NICU

Introduction & Objective: The main indication of mechanical ventilation is in the treatment of neonates with respiratory failure. With the increased use of mechanical ventilation, its complications have increased too. The aim of this study was to evaluate the prevalence of complications and short-term improvement in infants undergoing mechanical ventilation in the neonatal intensive care unit (...

متن کامل

Increased duration of mechanical ventilation is associated with decreased diaphragmatic force: a prospective observational study

INTRODUCTION Respiratory muscle weakness is an important risk factor for delayed weaning. Animal data show that mechanical ventilation itself can cause atrophy and weakness of the diaphragm, called ventilator-induced diaphragmatic dysfunction (VIDD). Transdiaphragmatic pressure after magnetic stimulation (TwPdi BAMPS) allows evaluation of diaphragm strength. We aimed to evaluate the repeatabili...

متن کامل

An Experience with Manual Ventilation in Respiratory Paralysis Due to Indian Common Krait (Bungarus Caeruleus) Bite

Background: Bungarus caeruleus (common krait) bite during monsoon season is common in northwest India. Respiratory failure is responsible for high mortality in the victims. In this study we report our experience with manual ventilation using bag valve mask (BVM) in patients with neuroparalysis due to common krait bite.  Methods:This prospective study was conducted between June 2009 and December...

متن کامل

Respiratory weakness is associated with limb weakness and delayed weaning in critical illness.

OBJECTIVE Although critical illness neuromyopathy might interfere with weaning from mechanical ventilation, its respiratory component has not been investigated. We designed a study to assess the level of respiratory muscle weakness emerging during the intensive care unit stay in mechanically ventilated patients and to examine the correlation between respiratory and limb muscle strength and the ...

متن کامل

خصوصیات، عوامل خطر و پیامدهای پنومونی ناشی از ونتیلاتور، در بیماران بستری در بخش مراقبت‌های ویژه نوزادان

Background: Ventilator Associated Pneumonia (VAP), developing in mechanically ventilated patients after 48 hours of mechanical ventilation, is the second most common nosocomial infection. Therefore, there is a vital need to study the etiology and risk factors associated with VAP in neonates.Methods: Neonates admitted to neonatal intensive care unit (NICU), over a period of one year and who requ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2016