Investigation of the Degree of Disorder of the Structure of Polymer Soft Contact Lenses Using Positron Annihilation Lifetime Spectroscopy PALS.
نویسندگان
چکیده
BACKGROUND Hydrogel and silicone-hydrogel polymeric materials are widely used in ophthalmology for the manufacture of contact lenses. An important aspect is the investigation of the structure of these materials. OBJECTIVES This study has been conducted in order to compare the degree of disorder and presence of free volumes in the internal structure of the polymeric soft contact lenses Omafilcon A (hydrogel) and Comfilcon A (silicone-hydrogel). Differences in the occurrence of trapping centers for positrons and free volumes between the types of investigated contact lenses have been demonstrated. MATERIAL AND METHODS Two types of polymeric contact lenses were used as materials: Omafilcon A (hydrogel) and Comfilcon A (silicone-hydrogel). The study was performed using positron annihilation lifetime spectroscopy (PALS). RESULTS When the results of the measurements has been obtained, a graphical curve has created to describe the relationship of the number of annihilation acts in time. Significant changes were observed between the contact lenses investigated in positron trapping in macropores (based on a two-state model) and the presence of free volumes (based on the Tao-Eldrup model). CONCLUSIONS The use of the positron annihilation two-state model made it possible to demonstrate that a higher positron trapping rate in macropores occurs in the silicone-hydrogel contact lens. Additionally, calculations using the Tao-Eldrup model show the existence of free volumes in both types of materials. The size and fraction of free volumes is much larger in the silicone-hydrogel contact lens.
منابع مشابه
Positron annihilation lifetime spectroscopy in nickel ferrite and iron oxide nanopowders
In this study, a positron annihilation lifetime spectrometer was set up and its resolution was optimized. The spectrometer is a fast-slow arrangement with time resolution of 250 ps. To obtain lifetime components and their intensities from analyzing positron annihilation lifetime spectrum, the Pascual software is used. Positrons are from a source of radioactive 22NaCl with 20 μCi activity enclos...
متن کاملStructural study of polymer hydrogel contact lenses by means of positron annihilation lifetime spectroscopy and UV–vis–NIR methods
A study has been conducted in order to determine presence of free volume gaps in the structure of structure of polymer hydrogel contact lenses made in phosphoryl choline technology and of the degree of defect of its structure. The study was made by means of positron annihilation lifetime spectroscopy. As a result of the conducted measurements, curves were obtained, which described numbers of co...
متن کاملAnalysis of free volumes and light transmission in hydrogel and silicone-hydrogel polymer contact lenses
The free volume holes and light transmission of hydrogel and silicone-hydrogel polymer contact lenses were investigated. As the material, the Proclear family (omafilcon A) of hydrogel contact lenses and the Biofinity family (comfilcon A) of silicone-hydrogel contact lenses were used. Positron annihilation lifetime spectroscopy was used to characterize geometrical sizes and fractions of the free...
متن کاملپایداری سامانه اندازهگیری طول عمر پوزیترون و بررسی نوع و غلظت عیب ناشی از تابش الکترونهای 10 مگا الکترون ولتی بر نمونههای سیلیکونی نوع n و p
Positron annihilation lifetime spectroscopy method with valuation of non-destructive investigation of material, provides information about electron density, defect concentration, type of defects and atoms around the defects. The stability of the system was tested with a source. The time resolution of the whole system has been derived about 365 ps at FWHM. Then n- and p-type silicon samples we...
متن کاملvidence for depth-dependent structural changes in freeze/thaw-cycled dry afion® using positron annihilation lifetime spectroscopy (PALS)
The effects of freeze/thaw (F/T) cycling on the structure of dry Nafion® membranes were investigated using positron annihilation lifetime spectroscopy (PALS). The method correlates the lifetime and relative intensity of positrons (anti-electrons) annihilating in the open-volume voids of the membrane with void size and void volume fraction. The results, though still preliminary, show freeze/thaw...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Polimery w medycynie
دوره 46 1 شماره
صفحات -
تاریخ انتشار 2016