High-resolution liquid chromatography of DNA fragments on non-porous poly(styrene-divinylbenzene) particles.
نویسندگان
چکیده
DNA restriction fragments and PCR products were separated by means of ion-pair reversed-phase high-performance liquid chromatography on alkylated non-porous poly(styrene-divinylbenzene) particles with a mean diameter of 2.1 microns. Optimum resolution was obtained by using an acetonitrile gradient in 100 mM of triethylammonium acetate and a column temperature of 50 degrees C. This allowed the separation of DNA fragments differing in chain length by 1-5% up to a size of 500 base pairs. PCR products could be analyzed directly in less than two minutes with a concentration sensitivity of at least 300 ng/ml. Compared with anion-exchange chromatography or gel electrophoresis no desaltation of the purified DNA molecules is required because the volatile buffer system can be readily evaporated. Subsequently, the method was used for the semiquantitative evaluation of the expression of multidrug resistance genes in mononuclear white blood cells.
منابع مشابه
Preparation of Porous Poly(Styrene-Divinylbenzene) Microspheres and Their Modification with Diazoresin for Mix-Mode HPLC Separations
By using the two-step activated swelling method, monodisperse porous poly(styrene-divinylbenzene) (P(S-DVB)) microparticles were successfully synthesized. The influence of porogens, swelling temperatures and crosslinking agents on the porosity of porous microparticles was carefully investigated. Porous P(S-DVB) microparticles were used as a packing material for high performance liquid chromatog...
متن کاملDenaturing high-performance liquid chromatography: A review.
Denaturing high-performance liquid chromatography (DHPLC) compares two or more chromosomes as a mixture of denatured and reannealed PCR amplicons, revealing the presence of a mutation by the differential retention of homo- and heteroduplex DNA on reversed-phase chromatography supports under partial denaturation. Temperature determines sensitivity, and its optimum can be predicted by computation...
متن کاملEvaluation of indoor exposition to benzene, toluene, ethylbenzene, xylene, and styrene by passive sampling with a solid-phase microextraction device.
A solid-phase microextraction (SPME) sampling method is developed to evaluate indoor exposure to benzene, toluene, ethylbenzene, xylene, and styrene with gas chromatography and flame ionization detection for quantitative analysis. An SPME holder with a 100-pm polydimethylsiloxane (PDMS) and 65-pm PDMS-divinylbenzene fiber coating is tested in different air relative humidity conditions. The meth...
متن کاملSeparation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملSeparation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nucleic acids research
دوره 21 5 شماره
صفحات -
تاریخ انتشار 1993