Determining entropy values equivalent to the bispectral index values during sevoflurane anaesthesia

نویسندگان

  • Canan Balcı
  • Hamit Karabekir
  • Remziye Sivaci
چکیده

INTRODUCTION We aimed to identify the entropy levels that would be equivalent to the bispectral index (BIS) levels in sevoflurane anaesthesia in patients who are to undergo elective lumbar disc surgery. MATERIAL AND METHODS Thirty cases in ASA groups I-II who underwent lumbar disc surgery under general anaesthesia were included in our study after obtaining the consent of the patients and Ethics Committee of our medical school between January 1, 2005 and October 30, 2006. BIS and entropy electrodes were applied at the same time in 30 cases in the study group. The depth of the anaesthesia was regulated so that 10 min after beginning the general anaesthesia the BIS values were between 40 and 60. At the same time equivalent entropy values corresponding to BIS values were obtained. RESULTS At the end of the study, entropy values corresponding to general anaesthesia BIS values were identified. General anaesthesia BIS and RE/SE values at 10 min were lower than the values of the control, which was statistically significant (p < 0.05). Equivalent entropy values were obtained lower than the BIS values during general anaesthesia and these values were found to be statistically significant (p < 0.05). The blood pressure (BP) values obtained were very low at equivalent BIS values and when these BP values were compared with the initial BP values they were found to be statistically significant (p < 0.05). CONCLUSIONS Based on this observation, we think that general anaesthetic agents that might cause severe hypotension could be more safely administered under entropy monitoring.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Bispectral Index and Entropy values with electroencephalogram during surgical anaesthesia with sevoflurane.

BACKGROUND Concomitantly recorded Bispectral Index® (BIS) and Entropy™ values sometimes show discordant trends during general anaesthesia. Previously, no attempt had been made to discover which EEG characteristics cause discrepancies between BIS and Entropy. We compared BIS and Entropy values, and analysed the changes in the raw EEG signal during surgical anaesthesia with sevoflurane. METHODS...

متن کامل

Wide inter-individual variability of bispectral index and spectral entropy at loss of consciousness during increasing concentrations of dexmedetomidine, propofol, and sevoflurane.

BACKGROUND The bispectral index (BIS) and the spectral entropy (state entropy, SE, and response entropy, RE) are depth-of-anaesthesia monitors derived from EEG and have been developed to measure the effects of anaesthetics on the cerebral cortex. We studied whether they can differentiate consciousness from unconsciousness during increasing doses of three different anaesthetic agents. METHODS ...

متن کامل

The performance of Bispectral Index in children during equi-MAC halothane vs. sevoflurane anaesthesia.

BACKGROUND AND OBJECTIVE The reliability of the Bispectral Index for evaluating and monitoring the depth of general anaesthesia in children is not as great as for that in adults. Therefore we analysed Bispectral Index performance in children by comparing changes in Bispectral Index values during a standardized and equipotent anaesthetic regimen using either halothane or sevoflurane for the indu...

متن کامل

Entropy indices vs the bispectral index for estimating nociception during sevoflurane anaesthesia.

BACKGROUND It is now possible to acquire and process raw EEG and frontal EMG signals to produce two spectral-entropy-based indices (response entropy and state entropy) reflective of analgesic and hypnotic levels during general anaesthesia (with the Datex-Ohmeda S/5 Entropy Module, Datex-Ohmeda, Helsinki, Finland). However, there are no data available on the accuracy of the Entropy Module in est...

متن کامل

Validation of the index of consciousness during sevoflurane and remifentanil anaesthesia: a comparison with the bispectral index and the cerebral state index.

BACKGROUND The purpose of this study was to validate a new level of consciousness monitor derived from the EEG, called the index of consciousness (IoC), by comparing it with the bispectral index (BIS) and the cerebral state index (CSI) during general anaesthesia for cardiac surgery using sevoflurane, remifentanil, and atracurium. METHODS After ethical committee approval and written patient co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2010