Poly-3-hydroxybutyrate (PHB): a resorbable conduit for long-gap repair in peripheral nerves.

نویسندگان

  • R C Young
  • M Wiberg
  • G Terenghi
چکیده

The repair of peripheral nerve injuries with an autologous nerve graft is still the treatment of choice, although it is widely recognised that the method is associated with donor-site morbidity and a suboptimal functional outcome. An alternative approach is to use a nerve conduit to provide a guidance channel for the regenerating nerve. This study investigates the potential of poly-3-hydroxybutyrate (PHB) nerve conduits to bridge long nerve gaps (up to 4 cm) in a rabbit common-peroneal-nerve injury model. Regeneration was assessed up to 63 days postoperatively, and compared with that achieved using nerve autografts. By 42 days, regenerating axons had bridged nerve gaps of all lengths in groups with nerve autografts and in those with PHB conduits. The regeneration distance increased with time but did not vary with gap length (P </= 0.009, 14 versus 21 days, PHB tube 2 cm, 3 cm and 4 cm, Mann-Whitney U -test). At 42 days, the area of immunostained regenerating fibres in the PHB group was greater than that in the nerve autograft group (P < 0.001, PHB versus autograft, 21 and 42 days, three-way analysis of variance (ANOVA)). These results suggest that PHB conduits support peripheral nerve regeneration up to 63 days, and that they are suitable for long-gap nerve injury repair.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advances of Peripheral Nerve Repair Techniques to Improve Hand Function: A Systematic Review of Literature

Concepts of neuronal damage and repair date back to ancient times. The research in this topic has been growing ever since and numerous nerve repair techniques have evolved throughout the years. Due to our greater understanding of nerve injuries and repair we now distinguish between central and peripheral nervous system. In this review, we have chosen to concentrate on peripheral nerve injuries ...

متن کامل

In vitro and in vivo degradation studies for development of a biodegradable patch based on poly(3-hydroxybutyrate).

For the development of a resorbable gastrointestinal patch, the in vitro degradation of solution-cast films of poly(3-hydroxybutyrate) (PHB), modifications of PHB expected to influence its degradation time, as well a poly(L-lactide) (PLLA) was examined. The molecular weight of pure PHB decreased by one-half after 1 year in buffer solution (pH 7.4, 37 degrees C). Acceleration in molecular weight...

متن کامل

Immunostimulatory and growth-promoting potential of poly-β-hydroxybutyrate in rainbow trout (Oncorhynchus mykiss) fingerlings culture

In the current study, the effect of dietary supplementation of poly-β-hydroxybutyrate (PHB) on growth performance, digestive enzymes activity, body composition, non-specific immune response and diseases resistance of rainbow trout fingerlings were investigated. Five hundred and fifty-two healthy fingerlings (8.2±1.0 g) were randomly distributed in 12 tanks (150 L) at a density of 46 fish/ tank ...

متن کامل

NERVE GAP REPAIR by the use of artificial conduits and cultured cells

Peripheral nerve injuries are often associated with loss of nerve tissue and require autologous nerve grafts to provide a physical substrate for axonal growth. This thesis investigates the use of fibrin as both a tubular conduit to guide nerve regeneration and also as a matrix material to suspend various regenerative cell types within/on poly-3-hydroxybutyrate (PHB) nerve conduits. Adipose deri...

متن کامل

Rat Sciatic Nerve Reconstruction Across a 30 mm Defect Bridged by an Oriented Porous PHBV Tube With Schwann Cell as Artificial Nerve Graft

An oriented poly(3-hydroxybutyrate-co-3-hydroxyvalerate) nerve conduit has been used to evaluate its efficiency based on the promotion of peripheral nerve regeneration in rats. The oriented porous micropatterned artificial nerve conduit was designed onto the micropatterned silicon wafers, and then their surfaces were modified with oxygen plasma to increase cell adhesion. The designed conduits w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of plastic surgery

دوره 55 3  شماره 

صفحات  -

تاریخ انتشار 2002