McGRATH MAC video laryngoscope for insertion of a transoesophageal echocardiography probe

نویسندگان

  • Takashi Ishida
  • Chiaki Kiuchi
  • Takemi Sekiguchi
  • Takatoshi Tsujimoto
  • Mikito Kawamata
چکیده

BACKGROUND Transoesophageal echocardiography (TOE) probe insertion in anaesthetised patients can cause pharyngeal and oesophageal injuries. Kim et al. have shown that insertion assisted by a Macintosh laryngoscope can reduce such complications but it may sometimes be difficult to observe the passage of a TOE probe. The McGRATH MAC (McGRATH) has been shown to provide a better view of the glottis, piriform fossa and oesophageal inlet during tracheal intubation than the Macintosh. OBJECTIVE We hypothesised that the McGRATH provided better visualisation of the oesophageal inlet and was useful as an aid to TOE probe placement, possibly reducing the incidence of pharyngeal injury related to insertion, compared with the Macintosh. DESIGN A randomised controlled trial. SETTING The study was conducted in a university hospital from February to December 2014. PATIENTS One hundred patients undergoing elective surgery under intraoperative TOE monitoring were randomised to either a Macintosh group or a McGRATH group. INTERVENTIONS Macintosh and McGRATH were used to visualise the passage of the TOE probe and guide its insertion. MAIN OUTCOME MEASURES Visibility of the oesophageal inlet, the number of TOE insertion attempts and incidence of pharyngeal mucosal injury after the TOE probe had been removed were assessed. RESULTS The percentage of patients in whom the oesophageal inlet was visible was higher in the McGRATH group (88%) than in the Macintosh group (41%) (P < 0.01). The number of TOE probe insertion attempts was significantly smaller in the McGRATH group than in the Macintosh group (P = 0.039). The incidence of pharyngeal mucosal injury was significantly smaller in the McGRATH group (4%) than in the Macintosh group (16%; P = 0.042). CONCLUSION The McGRATH provided a better view of the oesophageal inlet and was useful as an aid to TOE probe placement, possibly reducing the incidence of pharyngeal injury related to its insertion. TRIAL REGISTRATION University Hospital Medical Information Network in Japan (UMIN) 000012970.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Video laryngoscopy in pre-hospital critical care – a quality improvement study

BACKGROUND Pre-hospital endotracheal intubation is challenging and repeated endotracheal intubation is associated with increased morbidity and mortality. We investigated whether the introduction of the McGrath MAC video laryngoscope as the primary device for pre-hospital endotracheal intubation could improve first-pass success rate in our anaesthesiologist-staffed pre-hospital critical care ser...

متن کامل

Combined use of a McGrath® MAC video laryngoscope and Frova Intubating Introducer in a patient with Pierre Robin syndrome: a case report

Patients with Pierre Robin syndrome are characterized by micrognathia, retrognathia, glossoptosis, and respiratory obstruction and are prone to have a difficult-to-intubate airway. The McGrath® MAC video laryngoscope provides a better view of the glottis than a Macintosh laryngoscope, but it is not easy to insert an endotracheal tube through the vocal cords because a video laryngoscope has a mu...

متن کامل

The usefulness of the McGrath MAC laryngoscope in comparison with Airwayscope and Macintosh laryngoscope during routine nasotracheal intubation: a randomaized controlled trial

BACKGROUND McGrath MAC video laryngoscope offers excellent laryngosopic views and increases the success rate of orotracheal intubation in some cases. The aim of this study was to determine the usefulness of McGrath MAC for routine nasotracheal intubation by comparing McGrath MAC with Airway scope and Macintosh laryngoscope. METHODS A total of 60 adult patients with ASA physical status class 1...

متن کامل

Rigid laryngoscope-assisted insertion of transesophageal echocardiography probe reduces oropharyngeal mucosal injury in anesthetized patients.

BACKGROUND Intraoperative transesophageal echocardiography has become a routine part of monitoring in patients with cardiac disease. However, insertion of a transesophageal echocardiography probe can be associated with oropharyngeal, esophageal, and gastric injuries. The purpose of this study was to determine whether insertion of a transesophageal echocardiography probe under direct laryngoscop...

متن کامل

Comparison of the McGrath MAC video laryngoscope and the Pentax Airwayscope during chest compression: a manikin study

We tested the utility of the McGrath MAC(®) (McG) video laryngoscope during chest compression compared with the Pentax Airwayscope(®) (AWS). We recruited 59 participants into the simulation study. The difference in the time to intubation (TTI [sec]) between without and with chest compression was significant for the AWS attempts (median 13, range 6-28 vs. median 15, range 6-72, p = 0.0247) but n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 33  شماره 

صفحات  -

تاریخ انتشار 2016