Active Sampling Device for Determining Pollutants in Surface and Pore Water – the In Situ Sampler for Biphasic Water Monitoring

نویسندگان

  • Samuel D. Supowit
  • Isaac B. Roll
  • Viet D. Dang
  • Kevin J. Kroll
  • Nancy D. Denslow
  • Rolf U. Halden
چکیده

We designed and evaluated an active sampling device, using as analytical targets a family of pesticides purported to contribute to honeybee colony collapse disorder. Simultaneous sampling of bulk water and pore water was accomplished using a low-flow, multi-channel pump to deliver water to an array of solid-phase extraction cartridges. Analytes were separated using either liquid or gas chromatography, and analysis was performed using tandem mass spectrometry (MS/MS). Achieved recoveries of fipronil and degradates in water spiked to nominal concentrations of 0.1, 1, and 10 ng/L ranged from 77 ± 12 to 110 ± 18%. Method detection limits (MDLs) were as low as 0.040-0.8 ng/L. Extraction and quantitation of total fiproles at a wastewater-receiving wetland yielded concentrations in surface water and pore water ranging from 9.9 ± 4.6 to 18.1 ± 4.6 ng/L and 9.1 ± 3.0 to 12.6 ± 2.1 ng/L, respectively. Detected concentrations were statistically indistinguishable from those determined by conventional, more laborious techniques (p > 0.2 for the three most abundant fiproles). Aside from offering time-averaged sampling capabilities for two phases simultaneously with picogram-per-liter MDLs, the novel methodology eliminates the need for water and sediment transport via in situ solid phase extraction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Field performance of the Chemcatcher passive sampler for monitoring hydrophobic organic pollutants in surface water.

Six field trials were carried out to assess the performance of the Chemcatcher passive sampler alongside spot sampling for monitoring priority hydrophobic organic pollutants (polycyclic aromatic hydrocarbons (PAHs) and organochlorine pesticides) in a wide range of conditions in surface water. The trials were performed in three European rivers: Elbe (Czech Republic), Alna (Norway) and Meuse (Net...

متن کامل

Passive sampling of perfluorinated chemicals in water: in-situ calibration.

Perfluorinated chemicals (PFCs) have been recognised as environmental pollutants that require monitoring. A modified polar organic chemical integrative sampler (POCIS) is able to quantify aqueous PFCs. However, with varying external water velocity, PFC sampling rates (Rs) may change, affecting accuracy of derived water concentrations. To facilitate field deployment of this sampler, two methods ...

متن کامل

Taxonomy of benthic macroinvertebrates in Jajrud River for water quality assessment

The invertebrates are one of the most important terrestrial fauna and freshwater taxa.Benthic macroinvertebrates include aquatic insects and spiders, mites, crustaceans, andspecies of mollusks and worms that are aquatic in their immature stages and terrestrial intheir adult stage. Jajrud River originates from the Alborz Mountains and is a source of<br ...

متن کامل

An Automated Vacuum Extraction Control System for Soil Water Percolation Samplers

Duke et al. (1970) developed a mercury manometer and electrode-based controller for a soil water sampler A vacuum applied to soil water percolation samplers permits collecsystem. When coupled with a soil tensiometer, the detion of both macroand matrix-pore liquids. Performance of these field samplers is improved when the extraction vacuum is adjusted in vice automatically adjusted vacuum levels...

متن کامل

Dioxin analysis in water by using a passive sampler and CALUX bioassay.

Passive sampling of organic pollutants is a new trend in environmental monitoring and analysis. Passive samplers are being developed to overcome the drawbacks of the conventional snapshot sampling approach. The ceramic toximeter is a promising passive sampler for monitoring dioxin-contaminated surface and ground waters. It consists of an alumina cylinder lined with a thin coating of titania and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2016