Disinfection efficiency of secondary effluents with ultraviolet light in a Mediterranean area
نویسندگان
چکیده
This paper deals with the study of physicochemical and microbiological parameters affecting disinfection efficiency of secondary effluents in a municipal wastewater treatment plant, for irrigation purposes. There appears to be an important increase on turbidity values as chlorine values increases, due to the conversion of particulate organic carbon into dissolved organic carbon. The nitrification-denitrificacion processes appeared to be sensitive to changes in pH, with a minimum nitrate value in the wastewater when pH ranged between 7.018.00. With a similar behaviour, the phosphate removal was conditioned by pH, showing the highest efficiency in the same pH range. Both anions probed to be strongly correlated. Total coliforms were more UV light resistant than faecal coliforms, after an exposure of 10 min, corresponding to an UV dose of 73 mJ/cm. The experimental results for both groups of microorganisms followed first order reaction kinetics, with a gradual flattening at higher UV doses. A total elimination of both indicators would be achieved with doses over 95 mJ/cm. A previous step on the treated wastewater would improve its quality before the disinfection process.
منابع مشابه
Effects of Conventional Treatment, Tertiary Treatment and Disinfection Processes on Hygienic and Physico-Chemical Quality of Municipal Wastewaters
Conventional wastewater treatment, primary and secondary treatment processes with simultaneous phosphorus precipitation, is the most common process combination used in Finnish wastewater treatment plants (WWTPs). It typically eliminates most of the organic load and phosphorus, as well as part of the enteric microorganisms present in raw wastewater. Municipal secondary effluents still contain so...
متن کاملInfluence of wastewater disinfection on densities of culturable fecal indicator bacteria and genetic markers.
The US Environmental Protection Agency has proposed the use of quantitative polymerase chain reaction (qPCR) as a rapid alternative analytical method for monitoring recreational water quality at beaches. For qPCR to be considered for other Clean Water Act purposes, such as inclusion in discharge permits and use in Total Maximum Daily Load calculations, it is necessary to understand how qPCR det...
متن کاملTemperature-dependent change of light dose effects on E. coli inactivation during simulated solar treatment of secondary effluent
In this study, simulation of solar disinfection of secondary effluents was performed, to assess the dose effects, as instructed by the reciprocity law. A full factorial experimental design on the operational parameters of the process was performed (time, temperature, bacterial load, light intensity) and three response variables were estimated (disinfection efficiency, regrowth after 24, and 48 ...
متن کاملInvestigating the effect of different disinfection methods on the efficiency, pressure drop and Figure of merit of medical masks
Background and aim:This study was conducted with the aim of determining the effect of different disinfection methods on the efficiency,pressure drop and quality of medical masks used by medical staff. Also,the filtration efficiency of medical masks was investigated in the present study Materials and methods:In the present study, 4 models of medical masks used by the treatment staff were sele...
متن کاملInfectivity of Giardia duodenalis Cysts from UV Light-Disinfected Wastewater Effluent Using a Nude BALB/c Mouse Model
Giardia duodenalis is a protozoan of public health interest that causes gastroenteritis in humans and other animals. In the city of Campinas in southeast Brazil, giardiasis is endemic, and this pathogen is detected at high concentrations in wastewater effluents, which are potential reservoirs for transmission. The Samambaia wastewater treatment plant (WWTP) in the city of Campinas employs an ac...
متن کامل