A benchmark study on accuracy-controlled distance calculation between superellipsoid and superovoid contact geometries

نویسندگان

  • Artur Alves Gonçalves
  • Alexandre Bernardino
  • Joaquim Jorge
  • Daniel Simões Lopes
چکیده

Meshes are considered the gold standard regarding contact geometries of many mechanical models, even those represented with discrete surface contact elements. However, meshes may not be the best formulations when controlled precision and execution time become paramount. In this paper, we address parametric and implicit formulations for precise contact distance estimations between superovoidal shapes, which generalize superellipsoids. Parametric and implicit models provide more compact descriptions than meshes, while making it possible to approximate mechanical parts with great precision. Contrary to meshes, these geometric representations can then support fast calculation of distances with arbitrary precision without paying a storage or computation time penalty. We performed a benchmark study to compare different superellipsoidal and superovoidal contact geometry representations, including implicit surfaces, parametric surfaces and triangular meshes. We tested 10,0 0 0 contact pairs and also considered two application cases: robot fingers of an iCub and dental occlusion during bite. Our results show that the implicit model is the most efficient contact geometry representation, followed by parametric and mesh surfaces. In addition, results show that either implicit or parametric superovoids can provide more accurate distance estimations than meshes in practical settings where precise contact points, surface normals and clearance estimations are required. © 2017 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A superellipsoid-plane model for simulating foot-ground contact during human gait.

Musculoskeletal models and forward dynamics simulations of human movement often include foot-ground interactions, with the foot-ground contact forces often determined using a constitutive model that depends on material properties and contact kinematics. When using soft constraints to model the foot-ground interactions, the kinematics of the minimum distance between the foot and planar ground ne...

متن کامل

Implementation of D3Q19 Lattice Boltzmann Method with a Curved Wall Boundary Condition for Simulation of Practical Flow Problems

In this paper, implementation of an extended form of a no-slip wall boundary condition is presented for the three-dimensional (3-D) lattice Boltzmann method (LBM) for solving the incompressible fluid flows with complex geometries. The boundary condition is based on the off-lattice scheme with a polynomial interpolation which is used to reconstruct the curved or irregular wall boundary on the ne...

متن کامل

Accuracy of the Small Field Dosimetry Using the Acuros XB Dose Calculation Algorithm within and beyond Heterogeneous Media for 6 MV Photon Beams

Purpose: The dosimetric accuracy of the recently released Acuros XB advanced dose calculation algorithm (Varian Medical Systems, Palo Alto, CA) is investigated for single radiation fields incident on homogeneous and heterogeneous geometries, as well as for two arc (VMAT) cases and compared against the analytical anisotropic algorithm (AAA), the collapsed cone convolution superposition algorithm...

متن کامل

Incompressible laminar flow computations by an upwind least-squares meshless method

In this paper, the laminar incompressible flow equations are solved by an upwind least-squares meshless method. Due to the difficulties in generating quality meshes, particularly in complex geometries, a meshless method is increasingly used as a new numerical tool. The meshless methods only use clouds of nodes to influence the domain of every node. Thus, they do not require the nodes to be conn...

متن کامل

Monte Carlo calculation of proton ranges in water phantom for therapeutic energies

Introduction: One crucial point when calculating the distribution of doses with ions is the uncertainty of the Bragg peak. The proton ranges in determined geometries like homogeneous phantoms and detector geometries can be calculated with a number of various parameterization models. Several different parameterizations of the range-energy relationship exist, with different level...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017