A practical and reliable method for measuring ethane and pentane in expired air from humans.
نویسندگان
چکیده
We describe a method for the collection of expired air and further document the performance of our analytical technique that is used to measure ethane and pentane simultaneously. Four minutes of breathing hydrocarbon-free air before collection effectively removed high concentrations of residual ambient ethane and pentane from the lungs, with washout times up to 30 min resulting in no further reductions in breath hydrocarbons. Mean (+/-SE) exhalation rates (pmol/kg b.wt./min) in 11 subjects were 2.4 +/- 0.6 for ethane and 1.5 +/- 1.3 for pentane. Total intraindividual variability in exhalation rates (as percent coefficient of variation, %CV), measured from 4 subjects on at least 6 different days, was greater for pentane (44% CV) than for ethane (29% CV). Analytical variability contributed 6% to the total %CV. Advantages of the method are described, and reasons for the large variability in values reported in the literature are discussed.
منابع مشابه
Concentrating breath samples using liquid nitrogen: a reliable method for the simultaneous determination of ethane and pentane.
The measurement of ethane and pentane in breath offers a sensitive and noninvasive means to assess in vivo lipid peroxidation in animals and humans. However, numerous technical obstacles inherent in collecting and concentrating air-breath samples have limited the wider application of these measurements for the assessment of in vivo lipid peroxidation. We have developed a relatively simple, inex...
متن کاملTechnique for gas-chromatographic measurement of volatile alkanes from single-breath samples.
For detection of small quantities of alkanes that are present in expired breath, these gases have hitherto been concentrated, either by passing large volumes of breath through a liquid-nitrogen-cooled precolumn or by use of a closed collection system. Here, we describe a technique for analyzing small volumes of gas from single-breath samples from humans, in which no precolumn is required. Resul...
متن کاملPentane and isoprene in expired air from humans: gas-chromatographic analysis of single breath.
Both pentane and isoprene are excreted in human breath. Although pentane is considered an index of lipid peroxidation, the significance of isoprene is unknown. Having a similar boiling point, these two hydrocarbons are difficult to separate by gas chromatography. We separated pentane from isoprene on both a Poraplot Q and a Poraplot U column, injecting single-breath samples directly into a gas ...
متن کامل[Effect of dietary lipids on the toxicity of methylmercury in rats].
The effect of dietary lipids on the toxicity of methylmercury (MeHg) was investigated in experimental MeHg poisoning of rats. Three groups of weanling rats, with 8 to 12 animals in each group, were fed on vitamin E-deficient diet containing 10% beef tallow, cod liver oil or corn oil respectively for 5 weeks and the amount of plasma TBA (Thiobarbituric acid) -reactants, expired ethane and pentan...
متن کاملEthane and n-pentane in exhaled breath are biomarkers of exposure not effect.
The relationship of exhaled ethane and n-pentane to exhaled NO, carbonylated proteins, and indoor/outdoor atmospheric pollutants were examined in order to evaluate ethane and n-pentane as potential markers of airway inflammation and/or oxidative stress. Exhaled NO and carbonylated proteins were found to have no significant associations with either ethane (p = 0.96 and p = 0.81, respectively) or...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Free radical biology & medicine
دوره 27 5-6 شماره
صفحات -
تاریخ انتشار 1999