Effect of Haptic Material and Number of Intraocular Lens on Anterior Capsule Contraction after Cataract Surgery
نویسندگان
چکیده
PURPOSE To evaluate changes over time of the anterior capsule opening size after phacoemulsification, based on haptic number and composition of three acrylic intraocular lenses (IOLs). METHODS Fifty-five patients (70 eyes) were included. All underwent phacoemulsification followed by implantation of either an acrylic IOL with two-haptic (one-piece, 26 eyes; three-piece, 22 eyes), or four-haptic (one-piece, 22 eyes). The area of the anterior capsule opening size was measured one week postoperatively (baseline) and at three months. RESULTS There was a significant reduction in the area of the anterior capsule opening from one week as compared to three months postoperatively in all groups (p < 0.001). However, there was no significant difference in the reduction in the anterior capsule opening between the IOLs (p = 0.36). CONCLUSIONS The number and material of the haptic of the three acrylic IOLs did not influence the degree of anterior capsule opening shrinkage.
منابع مشابه
Effect of number and position of intraocular lens haptics on anterior capsule contraction: a randomized, prospective trial
BACKGROUND The present study aimed to evaluate the degree of anterior capsule contraction (capsulorhexis contraction) with three different single-piece, hydrophilic acrylic intraocular lenses (IOLs). METHODS Patients were prospectively randomized to be implanted with one of three types of IOLs during cataract surgery: the Ophtec Precizon (IOL A), the Lucid Korea Microflex (IOL B), and the Car...
متن کاملComparison of Anterior Capsule Stability Following Implantation of Three Single Piece Acrylic Intraocular Lenses with Different Haptic Design
PURPOSE To compare the anterior capsule contraction and intraocular lens (IOL) decentration among three types of IOL to determine the influence of haptic design on anterior capsule stability. METHODS One hundred fifty patients were enrolled in this prospective, randomized study and 260 eyes underwent implantation of one of the following IOLs: modified L-haptic IOL (n = 74), modified C-haptic ...
متن کاملSpontaneous Anterior Lens Capsular Dehiscence Causing Lens Particle Glaucoma
To report acute onset lens particle glaucoma associated with a spontaneous anterior capsular dehiscence. A 66-year-old man presented with spontaneous anterior lens capsule dehiscence with an acute onset of right eye pain that was associated with white particles in the anterior chamber angle and intraocular pressure (IOP) of 55 mmHg. No trauma or other inflammatory antecedents were reported. A h...
متن کاملTreatment of ophidism-induced bilateral canine cataract by extracapsular lens extraction and intraocular lens implantation
The aim of this study was to report a new cause of cataract, namely snake bite induced cataract in a dog. A 3-year-old male mongrel dog was referred to our clinic for the assessment of cataract in both eyes. The dog was bitten by a snake nearly 4 months ago. A 40 dioptre acrylic lens with 13 mm haptics was implanted into the lens capsule. In the left eye, posterior synechia was detected in the ...
متن کاملLens Epithelial Cell Death Secondary to Acanthamoeba Keratitis: Absence of Capsular Bag Opacification Six Years after Cataract Surgery
PURPOSE To show the evolution of anterior chamber structures 6 years after cataract surgery in a case with Acanthamoeba keratitis (AK). METHODS A 37-year-old woman with AK receiving long-term treatment with chlorhexidine, propamidine isethionate and steroids developed a white cataract and iris atrophy. Penetrating keratoplasty and cataract surgery were performed with subsequent intraocular pr...
متن کامل