Evaluation of a new rapid plasma reagin card test as a screening test for syphilis.
نویسندگان
چکیده
This study evaluates the American Dade (Biokit Laboratories) rapid plasma reagin (Dade RPR) card test, currently used in Spain for the diagnosis of syphilis, which has been recently released to the U.S. market. Used as a basis for comparison with the Dade card test were the 18-mm standard rapid plasma reagin (standard RPR) card test and the Venereal Disease Research Laboratory (VDRL) slide test, using both fresh sera obtained from 505 individuals and paired serum-plasma specimens from 174 individuals. Results obtained proved the Dade RPR card test with serum to be very similar to the standard RPR card test; sensitivity was 92.3% and specificity was approximately 99% for both RPR card tests. Although the sensitivity of the VDRL slide test was lower at 88.5%, its specificity was also approximately 99%. Quantitatively, the agreement +/- 1 dilution between the two card tests was 93.6%. Agreement +/- 1 dilution between the Dade RPR card test and the VDRL slide test was 46.5% for sera, comparable to the standard RPR-VDRL agreement of 50%. In the limited evaluation of the RPR card tests with plasma, the specificity was 99.4% and the sensitivity was 100% for both tests. Quantitative agreement +/- 1 dilution between plasma and serum pairs was 100% for the Dade RPR card test. Our results showed that the Dade RPR card test is as sensitive and as specific as the standard RPR card test. Therefore, it was concluded that one card test has no particular advantage over the other.
منابع مشابه
Evaluation of NCS rapid plasma reagin card test, a new screening kit for syphilis.
Agreements in qualitative and quantitative test results between the recently marketed NCS rapid plasma reagin card test (NCS Diagnostics Corp.) and the Macro-Vue rapid plasma reagin 18-mm circle card test (Hynson, Westcott and Dunning) were 99.2 and 99.1%, respectively, indicating the NCS RPR card test to be an acceptable alternative procedure for the serodiagnosis of syphilis.
متن کاملPractical Application of Quantitative HiSens Auto Rapid Plasma Reagin Latex Turbidimetric Immunoagglutination for Diagnosing Syphilis; Comparison Analysis between Rapid Plasma Reagin Latex Turbidimetric Immunoagglutination Test and Rapid Plasma Reagin Card Test
Background : The purpose of this study was to evaluate validity of quantitative RPR LTIA, HiSens Auto RPR LTIA (HBi Corp., South Korea) and to decide an adequate cutoff value for syphilis screening. Materials and Methods : A total of 549 serums or plasma specimens from patients were tested with RPR LTIA and RPR card tests. Degree of agreement between the two methods was analyzed, and validity o...
متن کاملComparison of a new rapid plasma reagin card test with the standard rapid plasma reagin 18-mm circle card test and the venereal disease research laboratory slide test for serodiagnosis of syphilis.
The rapid plasma reagin (RPR) card test manufactured by Beckman Instruments, Inc., was compared, qualitatively and quantitatively, with the Venereal Disease Research Laboratory (VDRL) slide test and the standard RPR 18-mm circle card tests for the serodiagnosis of syphilis. Sera from 638 individuals were used in this study. Two pilot lots and two production lots of antigen were submitted by Bec...
متن کاملFalse-positive reactions in the rapid plasma reagin-card, fluorescent treponemal antibody-absorbed, and hemagglutination treponemal syphilis serology tests.
Sera from 628 nonsyphilitic individuals were tested with the Rapid Plasma Reagin-Card, Fluorescent Treponemal Antibody-Absorbed, and Hemagglutination Treponemal Test for Syphilis tests to ascertain the comparative specificity of these tests. Many sera were also tested with the quantitative Venereal Disease Research Laboratory test. Sera included in the study were from both normal individuals an...
متن کاملPerformance of the rapid plasma reagin and the rapid syphilis screening tests in the diagnosis of syphilis in field conditions in rural Africa.
OBJECTIVES To assess the rapid plasma reagin (RPR) test performance in the field and to evaluate a new rapid syphilis test (RST) as a primary screen for syphilis. METHODS 1325 women of reproductive age from rural communities in the Gambia were tested for syphilis seropositivity using a RPR 18 mm circle card and a RST strip. Within 1 week a repeat RPR and a TPHA test were carried out using sta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 16 2 شماره
صفحات -
تاریخ انتشار 1982