Electromagnetic Interference in Implantable Rhythm Devices: Comment
نویسنده
چکیده
This is a short comment on the editorial on Electromagnetic Interference in Implantable Rhythm Devices The Indian Scenario in the July-September issue of the journal.1 Regarding the statement: "Systems working at 0.5 Tesla are available in the country so that it may be considered in such situations..." , though the author conveys his point, it gives reader a feeling that 0.5 Tesla magnetic resonance imaging (MRI) units are advantageous. In fact for every other diagnostic purpose we would like to have higher Tesla MRI units. The 0.5 Tesla unit is inferior compared to higher Tesla systems. The cry of Eastern European countries in a conference held in November 2001 at Antwerpen by the European Working Group on Management in Radiology (EWGMR), was that they have only 0.5 Tesla magnets and so they can not do this , that , no functional MRI , no stroke imaging etc etc... But a western European reader can get confused. I do not think there will be a single system working at 0.5 Tesla in countries like Germany.
منابع مشابه
Interference Between Cellular Telephones and Implantable Rhythm Devices: A Review on Recent Papers
BACKGROUND Cardiac pacemakers and implantable defibrillators are potentially susceptible to electromagnetic interferences as they have complex circuitry for sensing and communication purposes. Cellular telephones being an important source of electromagnetic waves are likely to cause interference in the function of these devices. METHODS A systematic analysis of studies on interaction between ...
متن کاملElectromagnetic Interference in Patients with Implanted Cardioverter-Defibrillators and Implantable Loop Recorders
Introduction: Modern life exposes us all to an ever-increasing number of potential sources of electromagnetic interference (EMI) and patients with Implantable rhythm devices (IRD) like pacemakers, implantable cardioverter defibrillators or implantable loop recorders often ask about the use of microwave ovens, walking through airport metal detectors and the use of cellular phones. Electromagneti...
متن کاملElectromagnetic Interference in Implantable Rhythm Devices - The Indian Scenario
Implantable rhythm device (IRD) is the generic name for the group of implantable devices used for diagnosis and treatment of cardiac arrhythmias. Devices in this category include cardiac pacemakers, implantable cardioverter defibrillators and implantable loop recorders. Since these devices have complex microelectronic circuitry and use electromagnetic waves for communication, they are susceptib...
متن کاملElectromagnetic Interference With Implantable Cardiac Devices
Although pacemakers and implantable cardioverter-defibrillators (ICDs) are subject to electromagnetic interference (EMI) from many sources, relatively few are capable of causing clinically significant interference. However, in the rapidly evolving technology -driven environment in which we live, new devices that could theoretically cause interference with implanted devices constantly appear bot...
متن کاملElectromagnetic interference between external defibrillator and cardiac resynchronization therapy-pacemaker (CRT-P) devices.
BACKGROUND Implantable heart rhythm devices are susceptible to interference in hospitals where electromagnetic interference (EMI) sources are ubiquitous. CASE DESCRIPTION We report three cases in which EMI from the external defibrillator caused the inability to interrogate Boston Scientific cardiac resynchronization therapy-pacemaker (CRT-P) devices. We have documented interference with the B...