Unplanned Extubation in a Mixed Intensive Care Unit
نویسندگان
چکیده
Background Identifying risk factors for unplanned extubation in patients receiving mechanical ventilation can help guide prevention strategies. Objective To assess the risk of unplanned extubation with different sedation strategies. Methods A 36-month quality improvement study in a 33-bed intensive care unit at a tertiary-care center. Results A total of 92 unplanned extubations occurred (7.5 events/1000 days of mechanical ventilation): patients who were receiving continuous sedation protocol with daily interruption of sedatives had 1.5 events/1000 ventilator days, patients receiving the intermittent sedation protocol had 5.0 events/1000 days, and patients with no sedation protocol had 16 events/1000 days (P < .05). Median duration of mechanical ventilation before unplanned extubation was 2 days. Most unplanned extubations (94%) were deliberate, and 53% occurred in patients scheduled for weaning. Most unplanned extubations in the continuous sedation protocol group (71%) occurred during weaning, in comparison to the intermittent sedation protocol (54%) and no sedation protocol groups (48%, P < .05). The highest incidences of agitation were in patients receiving the intermittent sedation protocol as compared with the other 2 groups (77% vs 50% vs 49%, P < .05). Overall, 73% of patients who had an unplanned extubation did not require reintubation; those who did were older (mean age: 68 vs 53 years, P = .01) and were male (80% vs 20%, P = .02). Reintubation was unrelated to the time of unplanned extubation. Conclusion Strategies of no sedation or intermittent sedation are both associated with higher rates of unplanned extubation when compared to a strategy of continuous sedation with daily interruption of sedatives. Sedation strategies that allow agitation may increase the risk of unplanned extubation. (American Journal of Critical Care. 2014;23:306-315) INFLUENCE OF SEDATION STRATEGIES ON UNPLANNED EXTUBATION IN A MIXED INTENSIVE CARE UNIT
منابع مشابه
Unplanned extubation in the ICU: a marker of quality assurance of mechanical ventilation
One of the most frequent complications associated with endotracheal intubation itself in intensive care units is unplanned extubation, which represents a potentially serious complication given that many patients may need reintubation while in poor condition. This scenario may account for an increase in morbidity and even in mortality. To be able to compare the rates of unplanned extubation in c...
متن کاملInfluence of sedation strategies on unplanned extubation in a mixed intensive care unit.
BACKGROUND Identifying risk factors for unplanned extubation in patients receiving mechanical ventilation can help guide prevention strategies. OBJECTIVE To assess the risk of unplanned extubation with different sedation strategies. METHODS A 36-month quality improvement study in a 33-bed intensive care unit at a tertiary-care center. RESULTS A total of 92 unplanned extubations occurred (...
متن کاملAssociated with Unplanned Extubations in a Surgical Intensive Care Unit
Background Unplanned extubations can result in serious complications. Objectives To determine characteristics of patients and nurses and risk factors that affect extubations. Methods A retrospective exploratory design was used. Ramsay Sedation Scale scores, need for reintubation, time between intubation and extubation, use of sedation and analgesia in the preceding 48 hours, and use of restrain...
متن کاملIncidence and primary causes of unplanned extubation in a neonatal intensive care unit.
OBJECTIVE This study established the incidence and primary causes of unplanned extubation in newborns in the neonatal intensive care units of the Hospital Sofia Feldman, Belo Horizonte (Minas Gerais). METHODS This retrospective study was conducted between July 1, 2009 and April 30, 2010. Unplanned extubations and their primary causes were assessed using an adverse events form. The following v...
متن کاملCharacteristics associated with unplanned extubations in a surgical intensive care unit.
BACKGROUND Unplanned extubations can result in serious complications. OBJECTIVES To determine characteristics of patients and nurses and risk factors that affect extubations. Methods A retrospective exploratory design was used. Ram-say Sedation Scale scores, need for reintubation, time between intubation and extubation, use of sedation and analgesia in the preceding 48 hours, and use of restr...