The effect of prolonged storage and disinfection on the dimensional stability of 5 vinyl polyether silicone impression materials

نویسندگان

  • Usama Nassar
  • Carlos Flores-Mir
  • Giseon Heo
  • Ysidora Torrealba
چکیده

PURPOSE Vinyl polyether silicone (VPES) has a different composition from other elastomeric impression materials as it combines vinyl polysiloxane (VPS) and polyether (PE). Therefore, it is important to study its properties and behavior under different test conditions. This study investigated the dimensional stability of 5 VPES consistencies when stored for up to 2 weeks, with and without using a standard disinfection procedure. MATERIALS AND METHODS 40 discs of each VPES consistency (total 200) were made using a stainless steel die and ring as described by ANSI /ADA specification No. 19. 20 discs of each material were immersed in a 2.5% buffered glutaraldehyde solution for 30 minutes. Dimensional stability measurements were calculated immediately after fabrication and repeated on the same discs after 7 and 14 days of storage. The data was analyzed using two-way ANOVA with a significance level set at α = 0.05. RESULTS The discs mean contraction was below 0.5% at all test times ranging from 0.200 ± 0.014 to 0.325 ± 0.007. Repeated measures ANOVA showed a statistically significant difference after 2-week storage between the disinfected and non-disinfected groups (P < .001). Although there was no statistically significant difference between the materials at the time of fabrication, the contraction of the materials increased with storage for 1 and 2 weeks. CONCLUSION The dimensional changes of VPES impression discs after disinfection and prolonged storage complied with ANSI/ADA standard. The tested VPES impression materials were dimensionally stable for clinical use after disinfection for 30 minutes in glutaraldehyde and storage for up to 2 weeks.

منابع مشابه

Dimensional measurement accuracy of recent polyether and addition silicone monophase impression materials after immersion in various disinfectants : An in vitro study

Introduction: The aim of this study was to evaluate and compare the long-term dimensional measurement accuracy of recent polyether and addition silicone monophase impression materials after their immersion in three disinfectants (dual phenol, 2% glutaraldehyde and 0.5% sodium hypochlorite) for 10 minutes and 1 hour. Methodology: Two standardized stainless steel dies were prepared (ADA specifica...

متن کامل

Effect of Three Disinfectants on Dimensional Changes of Different Impression Materials

Background and Aim: Disinfection of dental impression materials can alter their dimensional stability, which in turn can affect the accuracy of dental casts. This study aimed to determine the effect of three disinfectants on the dimensional changes of ir-reversible hydrocolloid impression materials and addition silicones. Materials and Methods: Forty alginate and 40 addition silicone impressio...

متن کامل

The effect of immersion disinfection procedures on dimensional stability of two elastomeric impression materials.

The aim of this study was to determine the effect of immersion disinfection procedures on the dimensional stability of two elastomeric impression materials. Impressions of a stainless steel die were made with polyether (PE) and with addition-polymerized silicone rubber (PVS). The test specimens underwent disinfection treatment by immersion in two commercially available solutions containing quat...

متن کامل

Dimensional accuracy of three impression materials by one-step and two-step impression techniques: An in vitro study

Introduction: An accurate impression is essential to create a well-fitted dental prosthesis. This study aimed to compare the dimensional accuracy of three elastomeric materials using one-step and two-step impression techniques. Methods: In this study, 20 impressions were fabricated for each Vinyl siloxane ether (Identium), condensation silicone (Speedex), and a...

متن کامل

Influence of disinfection with peracetic acid and hypochlorite in dimensional alterations of casts obtained from addition silicone and polyether impressions.

Dental impressions disinfection is important to reduce the risk of cross contamination but this process may produce dimensional distortions. Peracetic acid is a disinfectant agent with several favorable characteristics yet underutilized in Dentistry. The aim of this paper is to compare the dimensional stability of casts obtained from addition silicone and polyether impressions that were immerse...

متن کامل