A Simple Multi-objective Control for Cascaded Hydro Power Plants

نویسندگان

  • G. Robert
  • F. Michaud
چکیده

This paper presents a simple multi-objective control technique for cascaded hydro power plants, based on a centralized distributed power control system and local water level controllers. This effective power management solution enables to guarantee the generation program following with a very good accuracy, to participate to power-frequency Ancillary Services with the dynamic performance required and to control water levels in every canals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neural Cascaded with Fuzzy Scheme for Control of a Hydroelectric Power Plant

A novel design for flow and level control in a hydroelectric power plant using Programmable Logic Controller (PLC)-Human Machine Interface (HMI) and neural cascaded with fuzzy scheme is proposed. This project will focus on design and development of flow and level controller for small scale hydro generating units by implementing gate control based on PLC-HMI with the proposed scheme. The existin...

متن کامل

Automatic Generation Control of Thermal-Thermal-Hydro Power Systems with PID Controller using Ant Colony Optimization

In this work, Artificial Intelligence (AI) based Ant Colony Optimization (ACO) algorithm is proposed for Load Frequency Control (LFC) of interconnected multi–area hydrothermal power systems. Area 1&2 are thermal power systems and area 3 is a hydro power system, all the areas are interconnected through the appropriate tie-line. Thermal and hydro power plants are applied with reheat turbine and e...

متن کامل

Selective Harmonics Elimination Technique in Cascaded H-Bridge Multi-Level Inverters Using the Salp Swarm Optimization Algorithm

A new optimization method is proposed in this paper for finding the firing angles in multi-level voltage source inverters to eliminate low-order selective harmonics and reduce total harmonic distortion (THD) value of the output voltage. For thid end, Fourier series is used for calculating objective function and selecting specific harmonics. Regarding the nature and complexity of the employed no...

متن کامل

A Novel Controller Based on Single-Phase Instantaneous p-q Power Theory for a Cascaded PWM Transformer-less STATCOM for Voltage Regulation

In this paper, dynamic performance of a transformerless cascaded PWM static synchronous shunt compensator (STATCOM) based on a novel control scheme is investigated for bus voltage regulation in a 6.6kV distribution system. The transformerless STATCOM consists of a thirteen-level cascaded H-bridge inverter, in which each voltage source H-bridge inverter should be equipped with a floating and iso...

متن کامل

Short Term Hydrothermal Scheduling in Power System Using Improved Particle Swarm Optimization

The problem of determining the optimal hourly generation in hydrothermal power plants and total thermal generation is studied. A multi reservoir cascaded hydro-electric system with a non-linear relationship between water discharge rate, net head and power generation is considered. PSO technique has been motivated by the behavior of the organisms such as fish schooling and bird flocking. The ind...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -