Cardiac dose evaluation for 3Dimensional conformal partial breast irradiation compared with whole breast irradiation
نویسندگان
چکیده
To compare the radiation dose to normal cardiac tissue for 3Dimensional (3D) conformal external beam partial breast irradiation (PBI) and standard whole breast irradiation (WBI), and examine the effect of tumor bed location. For 14 patients with left breast tumors randomized on the National Surgical Adjuvant Breast and Bowel Project B-39 protocol, computer-generated radiotherapy treatment plans were devised for WBI and PBI. Tumor bed location was designated according to whether more than 50% of the excision cavity was medial or lateral to the nipple line. The volume of heart receiving doses of 2.5, 5, 10, and 20 Gy was calculated for all PBI and WBI plans. Dose to 5% of the heart volume (D5) and mean heart dose were also calculated. The biologically-equivalent dose (BED) was calculated to account for the different fractionation used in PBI and WBI. Of the 14 patients, 8 had lateral tumor beds, and 6 had medial tumor beds. The volumes of heart receiving 2.5, 5, 10, and 20 Gy were significantly lower for lateral PBI compared with WBI. For medial PBI, significant cardiac sparing was only seen at a dose of 20 Gy. The difference of D5 values was significant for lateral PBI compared with WBI (p=0.008), but not for medial PBI compared with WBI (p=0.84). The mean dose was also significantly lower for lateral PBI compared with WBI (p=0.008), but not for medial PBI (p=0.16). The results from BED calculations did not change this outcome. Both 3D conformal PBI and standard WBI can deliver relatively low doses to the heart. For patients with lateralized tumor beds, PBI offers significant cardiac sparing compared with WBI. Patients with medial lesions have relatively similar heart dosimetry with PBI and WBI. 3D conformal PBI is an emerging treatment modality and continued participation on clinical trials is encouraged. Patients with left-sided lesions and lateralized tumor beds warrant special consideration for PBI, given the significant cardiac dose sparing.
منابع مشابه
Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions
Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...
متن کاملA treatment planning study comparing whole breast radiation therapy against conformal, IMRT and tomotherapy for accelerated partial breast irradiation.
PURPOSE AND BACKGROUND Conventional early breast cancer treatment consists of a lumpectomy followed by whole breast radiation therapy. Accelerated partial breast irradiation (APBI) is an investigational approach to post-lumpectomy radiation for early breast cancer. The purpose of this study is to compare four external beam APBI techniques, including tomotherapy, with conventional whole breast i...
متن کاملDosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer
Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods: Twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. For each patient, two different treatment plans were cr...
متن کاملMeasurement of Mean Cardiac Dose for Various Breast Irradiation Techniques and Corresponding Risk of Major Cardiovascular Event
After breast conserving surgery, early stage breast cancer patients are currently treated with a wide range of radiation techniques including whole breast irradiation (WBI), accelerated partial breast irradiation (APBI) using high-dose rate (HDR) brachytherapy, or 3D-conformal radiotherapy (3D-CRT). This study compares the mean heart's doses for a left breast irradiated with different breast te...
متن کاملTreatment Techniques to Reduce Cardiac Irradiation for Breast Cancer Patients Treated with Breast-Conserving Surgery and Radiation Therapy: A Review
Thousands of women diagnosed with breast cancer each year receive breast-conserving surgery followed by adjuvant radiation therapy. For women with left-sided breast cancer, there is risk of potential cardiotoxicity from the radiation therapy. As data have become available to quantify the risk of cardiotoxicity from radiation, strategies have also developed to reduce the dose of radiation to the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2009