Comparison of automated and manual follicle monitoring in an unrestricted population of 100 women undergoing controlled ovarian stimulation for IVF.

نویسندگان

  • Baris Ata
  • Ayse Seyhan
  • Shauna Leigh Reinblatt
  • Einat Shalom-Paz
  • Srinivasan Krishnamurthy
  • Seang Lin Tan
چکیده

BACKGROUND Ovarian response to gonadotrophin stimulation is monitored with serial ultrasound (US) examinations. Sonography-based Automated Volume Count (SonoAVC) is a relatively new three-dimensional (3D) US technology, which automatically generates a set of measurements including the mean follicular diameter (MFD) and a volume-based diameter (d(V)) for each follicle in the ovaries. The present study aimed to assess the applicability and reproducibility of this automated follicle measurement method in an IVF programme. METHODS For this prospective method comparison study, 100 women undergoing US monitoring of a controlled ovarian stimulation cycle were recruited. Each follicle was manually measured by taking the mean of maximal diameters on three orthogonal planes with two-dimensional (2D) US. A 3D volume of each ovary was then captured. The ovarian volumes were later analysed using SonoAVC. The agreement between the two methods for the numbers of follicles and the size of the leading follicle was assessed with the Bland-Altman method. The reproducibility of SonoAVC measurements was assessed with the intraclass correlation coefficient (ICC). RESULTS Both SonoAVC-generated MFD and d(V)-based follicle counts, as well as the leading follicle diameter, had good agreement with conventional 2D US measurements. SonoAVC measurements had very good reproducibility, with ICC ≥0.8 for most evaluations. CONCLUSIONS Automated follicle monitoring with SonoAVC can replace or be used interchangeably with conventional 2D measurements. Automated follicle monitoring can save time, provide a method of quality control and create opportunities for developing HCG criteria based on follicular volume or for monitoring patients from a distance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

O-25: Serum Stem-Cell-Factor Assay in Elderly Poor Responder Patients Undergoing IVF: A New Biomarker to Customize Follicle Aspiration Cycle by Cycle.

Background Since the success rate in older poor-responder (POR) infertile women is expected to be extremely low irrespective of the treatment protocol, clinicians continue the search for biomarkers which may predict cases in which proceeding with follicle aspiration may be appropriate. Experimental studies on murine model suggest that SCF(Stem- Cell-Factor) produced by ovarian cumulus granulosa...

متن کامل

P-228: Low Dose HCG Adjunct to r-hFSH/GnRH Antagonist for Controlled Ovarian Stimulation in Assisted Reproductive Technology: A Prospective and Randomized Trial

Background: Deep suppression of LH in GnRH antagonist cycles may have detrimental effect on reproductive out come. It was hypnotized that adding LH activity via the administration of low dose HCG in late follicular phase shortened the duration of stimulation, decreased consumption of gonadotropin and increased estrogen levels. This study was designed to evaluate the effect of adding low dose HC...

متن کامل

Renal and Hepatic Functions After a Week of Controlled Ovarian Hyperstimulation During In Vitro Fertilization Cycles

Background One the main aspects of an in vitro fertilization (IVF) cycle is to avoid any possible systemic damage to women undergoing to a controlled ovarian hyperstimulation (COH). The aim of this work is to evaluate renal and hepatic function blood tests in patients undergoing controlled ovarian hyperstimulation during IVF cycles. MaterialsAndMethods All patients received a long stimulation p...

متن کامل

P-210: Evaluation of Anti-FSH Antibodies Levels as A Prognostic Marker in IVF Outcome

Background: The objective of this study is to establish importance of anti-FSH antibodies in IVF outcome. Materials and Methods: This research was designed based on evaluation of several articles from 2000 till 2012 about anti-FSH antibodies in IVF outcome. Results: Serum concentrations of anti-FSH IgG and IgA were linearly associated with poorer ovarian stimulation outcome. For example 1.0 AU ...

متن کامل

Pregnancy outcome following in vitro fertilization-embryo transfer (IVF-ET) in women aged < 37, undergoing ovulation induction with human FSH compared with recombinant FSH: a randomised controlled study.

OBJECTIVE To compare the pregnancy outcome in patients undergoing in vitro fertilization-embryo transfer (IVF-ET) cycles, using human derived follicle-stimulating hormone (FSH) or recombinant FSH for ovarian stimulation protocols. DESIGN Prospective, multi-centre, randomized controlled trial. PATIENTS 115 infertile patients undergoing a first attempt of in vitro fertilization and embryo tra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Human reproduction

دوره 26 1  شماره 

صفحات  -

تاریخ انتشار 2011