Noise Pickup and Filtering in the Chain of the AC Coupling Single-sided Silicon Microstrip Detectors and Frontend Electronics

نویسنده

  • Yoshinobu Unno
چکیده

The noise pickups and attenuations were simulated using the SPICE3 program for the detector and electronics chain of the ATLAS SCT Silicon microstrip detector module. Because of the use of the AC coupling single-sided detector, the filtering circuitry in the bias voltage supply lines should have an asymmetric setting in resistance. An effective way of reducing the pickup noise from the cooling pipe is also discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Proton Irradiation on AC-coupled Silicon Microstrip Detectors

To test the radiation tolerance of full-size detectors, four large-area AC-coupled single-sided silicon microstrip detectors were fabricated. The detectors had a size of 6 cm×3.4 cm and were made out of a 300 μm thick, high-resistivity, n-type silicon, simulating the p-side of the double-sided silicon microstrip detectors being developed. The AC coupling layer had either a single layer of SiO2 ...

متن کامل

Beam test results on n on n type silicon microstrip detectors before and after neutron irradiation

We present beam test results on AC-coupled, single-sided, n-on-n type silicon microstrip detectors. We have tested the detectors before and after irradiation at a fluence of 8.3× 10 n/cm, at different temperatures and bias voltages. The signal-to-noise ratio, spatial resolution, charge collection and overall efficiency have been measured.

متن کامل

Performance of the Silicon Detectors for the CMS Barrel Tracker

The Compact Muon Solenoid is a detector designed for the Large Hadron Collider. High particle rates combined with a magnetic field of 4 T make particle tracking a challenge. The baseline is to use silicon pixel and microstrip detectors and microstrip gas chambers. This talk focuses on the barrel part of the silicon tracker. It is made of 816 modules (368 single-sided and 448 double-sided) arran...

متن کامل

Signal-to-Noise in Silicon Microstrip Detectors with Binary Readout

We report the results of a beam test using double-sided ACcoupled silicon microstrip detectors with binary readout, i.e., a readout where the signals are discriminated in the front-end electronics and only the hit location as kept. For strip pitch between 50μm and 200μm, we determine the efficiency and the noise background as function of threshold setting. This allows us to reconstruct the Land...

متن کامل

Universit . . at Bonn Physikalisches Institut Performance of a Beam Telescope Using Double Sided Silicon Microstrip Detectors ?

A beam telescope consisting of four double sided, DC coupled microstrip detectors with VLSI readout electronics has been built and tested in a 70 GeV ? beam at CERN. A signal to noise ratio of 53:1 and a spatial resolution of 2.7m (junction side) and 4.8m (ohmic side) have been observed on the best detectors. A telescope performance for a particle track of xy = 2 ? 3 m and slope = 2 ? 3 rad on ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007