Sodium MRI using a density-adapted 3D radial acquisition technique.
نویسندگان
چکیده
A density-adapted three-dimensional radial projection reconstruction pulse sequence is presented which provides a more efficient k-space sampling than conventional three-dimensional projection reconstruction sequences. The gradients of the density-adapted three-dimensional radial projection reconstruction pulse sequence are designed such that the averaged sampling density in each spherical shell of k-space is constant. Due to hardware restrictions, an inner sphere of k-space is sampled without density adaption. This approach benefits from both the straightforward handling of conventional three-dimensional projection reconstruction sequence trajectories and an enhanced signal-to-noise ratio (SNR) efficiency akin to the commonly used three-dimensional twisted projection imaging trajectories. Benefits for low SNR applications, when compared to conventional three-dimensional projection reconstruction sequences, are demonstrated with the example of sodium imaging. In simulations of the point-spread function, the SNR of small objects is increased by a factor 1.66 for the density-adapted three-dimensional radial projection reconstruction pulse sequence sequence. Using analytical and experimental phantoms, it is shown that the density-adapted three-dimensional radial projection reconstruction pulse sequence allows higher resolutions and is more robust in the presence of field inhomogeneities. High-quality in vivo images of the healthy human leg muscle and the healthy human brain are acquired. For equivalent scan times, the SNR is up to a factor of 1.8 higher and anatomic details are better resolved using density-adapted three-dimensional radial projection reconstruction pulse sequence.
منابع مشابه
Sodium MRI of the human heart at 7.0 T: preliminary results.
The objective of this work was to examine the feasibility of three-dimensional (3D) and whole heart coverage (23)Na cardiac MRI at 7.0 T including single-cardiac-phase and cinematic (cine) regimes. A four-channel transceiver RF coil array tailored for (23)Na MRI of the heart at 7.0 T (f = 78.5 MHz) is proposed. An integrated bow-tie antenna building block is used for (1)H MR to support shimming...
متن کامل2D Radial Acquisition Technique with Density Adaption in Sodium MRI
Introduction: In this work we propose a 2D projection reconstruction method with variable gradient amplitudes to cover the k-space uniformly, as described elsewhere for the 3D case [1]. Signal-to-noise ratio is increased and the linear form of the radial trajectory is kept contrary to the twisting radial-line (TWIRL) trajectory [2] and interleaved spiral trajectory [3]. This method can be easil...
متن کامل3D Radial Twisted Projection Imaging for DCE-MRI with Variable Flip Angles
Introduction Radial acquisition schemes are used in dynamic contrast enhanced MRI (DCE-MRI) [1] due to superior motion insensitivity achieved by a repeated sampling of the k-space center each repetition time (TR). This also enables the use of k-space weighted image contrast (KWIC) [1] or sliding window reconstruction [2]. One disadvantage of radial acquisition schemes, especially in 3D imaging,...
متن کاملInaugural - Dissertation
zur nichtinvasiven Evaluation der Gewebevitalität darstellen. The goal of this work was to provide techniques and hardware for 23 Na MRI of the human brain, heart and muscle in a clinical scanner at 1.5 T. For this purpose, radiofrequency (RF) coils were developed and a transmit/receive switch was adapted to 16.84 MHz. A 3D radial gradient echo (GRE) sequence was implemented, with a minimum ech...
متن کاملOptimized Chemical Shift Imaging for Sodium MRI of the Human Brain
sequence with minimized acquisition delays (left). The duration of each gradient is minimized individually. Thus the acquisition delay depends on the k-space position (right). Figure 2: Central slices of a phantom containing 0.9% saline solution measured with the normal 3D-CSI sequence (a), the 3D-TEMin CSI sequence with minimized acquisition delay (b),the 3D-AW-CSI sequence with acquisition we...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 62 6 شماره
صفحات -
تاریخ انتشار 2009