Acoustic Detection of Coronary Occlusions before and after Stent Placement Using an Electronic Stethoscope

نویسندگان

  • Andrei Dragomir
  • Allison Post
  • Yasemin M. Akay
  • Hani Jneid
  • David Paniagua
  • Ali Denktas
  • Biykem Bozkurt
  • Metin Akay
چکیده

More than 370,000 Americans die every year from coronary artery disease (CAD). Early detection and treatment are crucial to reducing this number. Current diagnostic and disease-monitoring methods are invasive, costly, and time-consuming. Using an electronic stethoscope and spectral and nonlinear dynamics analysis of the recorded heart sound, we investigated the acoustic signature of CAD in subjects with only a single coronary occlusion before and after stent placement, as well as subjects with clinically normal coronary arteries. The CAD signature was evaluated by estimating power ratios of the total power above 150 Hz over the total power below 150 Hz of the FFT of the acoustic signal. Additionally, approximate entropy values were estimated to assess the differences induced by the stent placement procedure to the acoustic signature of the signals in the time domain. The groups were identified with this method with 82% sensitivity and 64% specificity (using the power ratio method) and 82% sensitivity and 55% specificity (using the approximate entropy). Power ratios and approximate entropy values after stent placement are not statistically different from those estimated from subjects with no coronary occlusions. Our approach demonstrates that the effect of stent placement on coronary occlusions can be monitored using an electronic stethoscope.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Stent Expansion by Stent Balloon Multiple Inflation at Nominal Pressure in Resistant Lesions: A New Technique

Introduction: This study aimed to evaluate the effects of four-time inflation of the stent balloon at nominal pressure on optimal stent expansion in resistant lesions. Materials and Methods: This interventional study was conducted on 39 patients with coronary artery lesions, in whom Zotarolimus-eluting stents (N=20), Paclitaxel-eluting stents (N=11) and other stents (N=8) were deployed four tim...

متن کامل

Safety, Efficacy and Clinical Outcome of Direct Stent Implantation

Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...

متن کامل

Subclavian artery-esophageal fistula after placement of a self-expanding metal stent in a patient with esophagogastric anastomosis stenosis

Background: There have been reports on stent-related vascular erosions about patients with benign or malignant stenosis of the esophagus who received endoscopic stent insertion for palliative intention for oral intake. Case presentation: A 61-year-old woman with esophageal cancer located in the middle part of esophagus was treated with esophagectomy. Two years following the surgery, malignan...

متن کامل

In vivo magnetic resonance imaging of coronary thrombosis using a fibrin-binding molecular magnetic resonance contrast agent.

BACKGROUND The advent of fibrin-binding molecular magnetic resonance (MR) contrast agents and advances in coronary MRI techniques offers the potential for direct imaging of coronary thrombosis. We tested the feasibility of this approach using a gadolinium (Gd)-based fibrin-binding contrast agent, EP-2104R (EPIX Medical Inc), in a swine model of coronary thrombus and in-stent thrombosis. METHO...

متن کامل

Coronary Artery Disease Identification Using Acoustic Features Based on QDA

Optimizing risk assessment may reduce use of advanced diagnostic testing in patients with symptoms suggestive of stable coronary artery disease (CAD). Detection of diastolic murmurs from post-stenotic coronary turbulence with an acoustic sensor placed on the chest wall can serve as an easy, safe, and low-cost supplement to assist in the diagnosis of CAD. Coronary artery disease (CAD) accounts f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Entropy

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2016