Somatotropin as measured by a two-site time-resolved immunofluorometric assay.

نویسندگان

  • C Strasburger
  • G Barnard
  • L Toldo
  • B Zarmi
  • Z Zadik
  • A Kowarski
  • F Kohen
چکیده

To date, many of the current criteria for diagnosis of somatotropin (growth hormone, GH) deficiency have been based upon measurement of this hormone by competitive radioimmunoassay (RIA) with use of polyclonal antibodies. In recent years, however, the development of hybridoma technology has led to the generation of various monoclonal antibodies (Mabs) to GH with different affinities and epitope specificities. Subsequently, these reagents have been used in the development of noncompetitive two-site immunometric assays (e.g., immunoradiometric assay; IRMA). In general, the values obtained for serum GH by IRMA have been lower than those obtained by RIA, because of the epitope-specificity profile of the Mabs in the IRMA. Attempting to obtain GH values numerically similar to those by RIA, we used a combination of Mabs to GH in developing and evaluating a two-site time-resolved immunofluorometric assay (IFMA) based on the streptavidin-biotin interaction. Fluorescence is proportional to concentration of analyte and is linearly related to concentration over the range 0.3 to 40 micrograms/L. The assay was satisfactory with respect to sensitivity, accuracy, and precision (CV less than 10% over the entire working range). In addition, the concentration of GH was determined by the IFMA and a competitive RIA in serum obtained from GH deficient and acromegalic patients. The pairing of antibodies in the IFMA gave numerical values that agreed well with those by RIA (r = 0.97; n = 100).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two-site time-resolved immunofluorometric assay of human insulin.

We describe a two-site "sandwich"-type time-resolved immunofluorometric assay for human insulin, based on use of two monoclonal antibodies with different specificities. The first antibody is immobilized on the surface of microtiter plate strip wells, the other is labeled with Eu3+. Serum samples can be assayed with one incubation step; two incubation steps are required when plasma samples are a...

متن کامل

Development of time-resolved immunofluorometric assay of vascular permeability factor.

We describe a two-site time-resolved immunofluorometric assay for guinea pig vascular permeability factor (VPF) for quantifying VPF in different biological fluids. Antibody against the carboxy terminus (C-IgG) is immobilized on microtiter wells, and antibody against the amino terminus (N-IgG) is labeled with Eu(3+)-chelate. Line 10 tumor culture medium, known to be rich in VPF, is assayed in a ...

متن کامل

Cyclosporlne Concentrations In Plasma at 37#{176}C Are Not PredIctable from ConcentratIons Measured In Whole Blood at Room Temperature, Paula Suit,

CLINICALCHEMISTRY, Vol.34, No. 3, 1988 597 References 1. Toivonen E, Hemmila I, Marniemi J, et al. Two-site timeresolved immtmofluorometric assay of human insulin. Clin Chem 1986;32:637-40. 2. BadorR, D#{233}chaud H, Claustrat F, DeauzmgesC. Europium and samarium as labels in time-resolved immunofluorometric assay of follitropin. Clin Chem 1987;33:48-51. 3. Leery JJ, Brigati DJ, Ward DC. Rapida...

متن کامل

Europium and samarium as labels in time-resolved immunofluorometric assay of follitropin.

This time-resolved immunofluorometric assay for human follitropin involves use of europium- or samarium-labeled monoclonal antibodies, with an average incorporation ratio of 3 mol of Eu3+ or Sm3+ per mole of antibody. These lanthanide ions are bound to the antibody molecules by means of the anhydride of diethylenetriaminepentaacetic acid. The solid-phase antibody is immobilized inside polystyre...

متن کامل

Time-resolved fluoroimmunoassay of human pancreatic phospholipase A2.

We describe an immunofluorometric assay for human pancreatic phospholipase A2 based on time-resolved fluorescence. The labeled antibody technique in combination with the time-resolved 1-s fluorometric detection of the europium label, which essentially eliminates all background fluorescence, resulted in a high sensitivity (20 ng/L) and a wide (5000-fold) linear range. Nonspecific binding was min...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 35 6  شماره 

صفحات  -

تاریخ انتشار 1989