Maximum Stable Drop Diameter in Stirred Dispersions

نویسنده

  • Andrew Lam
چکیده

Transient drop-size distributions of stirred dispersions undergoing breakage were experimentally measured at long stining times. The results show that drops continue to break the entire duration of the experiment (at least up to 10 h) and force a reevaluation of the widely held concept of a maximum stable drop diameter, d,,,. Transient distributions show the existence of self-similarity, which is the same as that observed in transient distributions obtained at short times (up to 1 h, Sathyagal et al., 1995b) indicating that the nature of breakage does not change with time. The existence of similarity at long stirring times can be used to obtain good estimates of breakage rates of small drops by an inverse problem procedure.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-scale Simulations of Stirred Liquid--liquid Dispersions

Direct numerical simulations (DNS) of liquid–liquid dispersions in a three-dimensional periodic domain have been performed by means of the lattice–Boltzmann method. The dispersion was agitated by a random force field such as to produce isotropic turbulence. The turbulence levels and its history were based on a fluid parcel in a turbulently stirred tank traversing the impeller swept region. The ...

متن کامل

A Model for Transitional Breakage Probability of Droplets in Agitated Lean Liquid-liquid Dispersions

Abstract-A model for transItional breakage probabfity of droplets m astated lean bqmd-hqmd dlsperslons IS proposed based on the mechamsm of breakage of droplets due to theu osculations resultmg from relative velocity Ructuahons A umvcrsal translhonal breakage probabhty m terms of non-dunenslonahzed drop diameter IS denved for all dispersed phases whose density and viscosity are almost the same ...

متن کامل

Presenting an Empirical Correlation for Maximum Sauter Mean Diameter in a Spray Extraction Column

Based on the importance of drops' behavior in liquid-liquid extraction, the maximum sauter mean drop diameter has been investigated and correlated in a counter-current spray extraction column with two chemical systems. Spargers were set of nozzles in all experiments. Studying the effects of several parameters on drops size, some correlations were estimated by the last available version of softw...

متن کامل

مدل سازی، طراحی و ساخت راکتور بستر ثابت واکنش تجزیه ی کاتالیستی هیدرازین

In this research, first, a one-dimensional stable model for a catalytic stabilization reactor is presented. All mass transfer, heat transfer and momentum equations are considered in this model with applying appropriate assumptions. The results of modeling predict temperature and concentration changes and also pressure drop along the reactor bed length. By applying the modeling, hydrazine cataly...

متن کامل

Determination of Coalescence Frequencies in Liquid-liquid Dispersions: Effect of Drop Size Dependence

The size dependence of the drop coalescence frequency is investigated by measurement of transient drop size distributions in purely coalescing systems (with negligible drop break-up). A twopronged approach is employed to estimate the bivariate coalescence frequency function, using such experimental data. First, coalescence frequency expressions derived from mechanistic models of the relative mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004