Noninvasive evaluation of coronary artery bypass grafts and native coronary arteries: is 16-slice multidetector CT useful?

نویسندگان

  • Aysel Türkvatan
  • Senay Funda Biyikoğlu
  • Fatma Gül Büyükbayraktar
  • Turhan Cumhur
  • Erdal Duru
  • Tülay Olçer
  • Mahmut Mustafa Ulaş
چکیده

PURPOSE To investigate the diagnostic accuracy and limitations of 16-slice multidetector computed tomography (MDCT) in the detection of significant ( > 50%) stenosis of coronary artery bypass grafts (CABG) and native coronary arteries. MATERIALS AND METHODS One hundred two patients with 236 grafts were investigated by 16-slice MDCT. Native coronary arteries were also investigated. The image quality was assessed in terms of artifact, and the evaluable segments were screened for the presence of occlusion and significant ( > 50%) stenosis. MDCT results were compared with conventional coronary angiography. RESULTS The evaluability of MDCT was 90.4% for CABG and 71.2% for native coronary arteries. The most frequent causes of nonevaluable segments were motion artifact in venous grafts, metallic clip artifact in arterial grafts, and severe calcification in native coronary arteries. MDCT correctly diagnosed all of the 46 occluded grafts. The sensitivity, specificity, and the positive and negative predictive value of MDCT for the detection of significant CABG stenoses were 91.4%, 98.5%, 84.2%, and 99.2%, respectively. Including nonevaluable segments in the analysis, overall sensitivity was 84.2%. For the evaluation of native coronary arteries, MDCT had a sensitivity of 82.1% and a specificity of 75.3%, but evaluability was only 71.2%, resulting in overall sensitivity of 62.1%. CONCLUSION Use of 16-slice MDCT angiography allows very accurate evaluation of CABG patency and has high diagnostic accuracy in detecting graft stenoses. But evaluation of native coronary artery stenosis is limited, particularly in patients with advanced coronary artery disease with severe calcification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic accuracy of noninvasive coronary angiography in patients after bypass surgery using 64-slice spiral computed tomography with 330-ms gantry rotation.

BACKGROUND Multidetector computed tomographic angiography (MDCT) has been shown to allow detection of coronary artery bypass graft (CABG) occlusions and stenoses. However, the assessment of native coronary arteries in addition to CABG has thus far not been sufficiently validated. METHODS AND RESULTS Fifty patients with a total of 138 CABG (34 mammary grafts, 3 radial grafts, 101 venous grafts...

متن کامل

Non-invasive assessment of coronary artery bypass grafts and native coronary arteries using 64-slice computed tomography: comparison with invasive coronary angiography.

INTRODUCTION AND OBJECTIVES Although the diagnostic accuracy of CT in the non-invasive assessment of coronary arteries and grafts is known to be high, only a few studies have investigated the technique's reliability for the combined assessment of native coronary arteries, grafts, and vessels lying distal to anastomoses. The aim of this study was to evaluate the diagnostic accuracy of 64-slice C...

متن کامل

The role of 16-slice computed tomography angiography in the diagnosis of coronary artery disease: large sample analysis.

BACKGROUND Computed tomography angiography enables non-invasive evaluation of the coronary arteries. OBJECTIVES To evaluate the accuracy of 16-slice multi-detector CT angiography in the diagnosis of coronary artery disease, and assess coronary bypass grafts and coronary anomalies. METHODS We conducted a retrospective study of 223 patients who were examined at our medical center over a perio...

متن کامل

A pictorial review of coronary artery bypass grafts at multidetector row CT.

Multidetector row CT scanners with submillimeter spatial resolution and high temporal resolution are now available and are increasingly used for noninvasive assessment of vascular disease including coronary arteries and grafts. The entire heart and graft course can be scanned within a single breath-hold, and contrast-enhanced images are reconstructed through retrospective ECG gating. In this pi...

متن کامل

Role of multidetector CT in the evaluation of coronary artery bypass grafts

Coronary artery bypass graft (CABG) surgery is associated with an improvement of survival and quality of life in patients with multivessel coronary disease and left main stenosis. However CABGs, similarly to the native coronary vessels, may in time, develop stenosis or occlusion. Invasive coronary angiography is considered the gold standard in the evaluation of CABG, but the technique is associ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diagnostic and interventional radiology

دوره 15 1  شماره 

صفحات  -

تاریخ انتشار 2009