Three-Directional Evaluation of Mitral Flow in the Rat Heart by Phase-Contrast Cardiovascular Magnetic Resonance.

نویسندگان

  • Kristine Skårdal
  • Emil K S Espe
  • Lili Zhang
  • Jan Magnus Aronsen
  • Ivar Sjaastad
چکیده

PURPOSE Determination of mitral flow is an important aspect in assessment of cardiac function. Traditionally, mitral flow is measured by Doppler echocardiography which suffers from several challenges, particularly related to the direction and the spatial inhomogeneity of flow. These challenges are especially prominent in rodents. The purpose of this study was to establish a cardiovascular magnetic resonance (CMR) protocol for evaluation of three-directional mitral flow in a rodent model of cardiac disease. MATERIALS AND METHODS Three-directional mitral flow were evaluated by phase contrast CMR (PC-CMR) in rats with aortic banding (AB) (N = 7) and sham-operated controls (N = 7). Peak mitral flow and deceleration rate from PC-CMR was compared to conventional Doppler echocardiography. The accuracy of PC-CMR was investigated by comparison of spatiotemporally integrated mitral flow with left ventricular stroke volume assessed by cine CMR. RESULTS PC-CMR portrayed the spatial distribution of mitral flow and flow direction in the atrioventricular plane throughout diastole. Both PC-CMR and echocardiography demonstrated increased peak mitral flow velocity and higher deceleration rate in AB compared to sham. Comparison with cine CMR revealed that PC-CMR measured mitral flow with excellent accuracy. Echocardiography presented significantly lower values of flow compared to PC-CMR. CONCLUSIONS For the first time, we show that PC-CMR offers accurate evaluation of three-directional mitral blood flow in rodents. The method successfully detects alterations in the mitral flow pattern in response to cardiac disease and provides novel insight into the characteristics of mitral flow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accurate and reproducible mitral valvular blood flow measurement with three-directional velocity-encoded magnetic resonance imaging.

A new method for quantifying the transvalvular flow through the mitral valve (MV) based on three-directional velocity-encoded magnetic resonance imaging (MRI) is presented. For thirty time phases during one cardiac cycle, the three-dimensional (3D) velocity vector field of the blood flow is reconstructed from the MRI measurement. Retrospectively, for each time phase, the MV-plane is indicated m...

متن کامل

Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance

BACKGROUND Phase contrast cardiovascular magnetic resonance (CMR) is able to measure all three directional components of the velocities of blood flow relative to the three spatial dimensions and the time course of the heart cycle. In this article, methods used for the acquisition, visualization, and quantification of such datasets are reviewed and illustrated. METHODS Currently, the acquisiti...

متن کامل

Visualization of vascular hemodynamics in a case of a large patent ductus arteriosus using flow sensitive 3D CMR at 3T.

Comprehensive flow velocity acquisition based on time-resolved three-dimensional phase-contrast CMR with three-directional velocity encoding was employed to assess arterial hemodynamics in a patient with a large patent ductus arteriosus with Eisenmenger's physiology. Computer-aided visualization of blood flow characteristics provided detailed information about temporal and spatial distribution ...

متن کامل

Three dimensional three component whole heart cardiovascular magnetic resonance velocity mapping: comparison of flow measurements from 3D and 2D acquisitions

BACKGROUND Two-dimensional, unidirectionally encoded, cardiovascular magnetic resonance (CMR) velocity mapping is an established technique for the quantification of blood flow in large vessels. However, it requires an operator to correctly align the planes of acquisition. If all three directional components of velocity are measured for each voxel of a 3D volume through the phases of the cardiac...

متن کامل

Flow measurement by magnetic resonance: a unique asset worth optimising.

Users and manufacturers of cardiovascular magnetic resonance (CMR) systems have, potentially, an unrivalled asset. Phase contrast mapping of velocities through planes transecting the great arteries should provide the most accurate measurements available of cardiac output, shunt flow, aortic or pulmonary regurgitation and, indirectly, of mitral regurgitation. But the reality is that phase contra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • PloS one

دوره 11 3  شماره 

صفحات  -

تاریخ انتشار 2016