Biodistribution and radiation dosimetry of radioiodinated hypericin as a cancer therapeutic.
نویسندگان
چکیده
Iodine-131‑labeled monoiodohypericin (131I‑Hyp) is a necrosis avid compound used as a complementary anticancer agent. Herein, the biodistribution in rats with re-perfused partial liver infarction (RPLI) was used to estimate its human internal radiation dosimetry. Iodine-123‑labeled monoiodohypericin (123I-Hyp) as a safer surrogate for 131I-Hyp was prepared with iodogen as oxidant. Determination of radiochemical yield and purification was performed by high performance liquid chromatography (HPLC). To control aggregation, the formulation was macroscopically and microscopically examined. Biodistribution of 123I-Hyp was studied in RPLI rats (n=18) at 4, 24 and 48 h post-injection. Tissue gamma counting (TGC), autoradiography and histology were performed. Dosimetry of 131I-Hyp in hepatic necrosis and in normal human organs was estimated using biodistribution data of 123I-Hyp, the Organ Level Internal Dose Assessment/Exponential Modeling (OLINDA/EXM®), a sphere model and male and female phantoms. A radiochemical yield of 95% was achieved in labeling of 123I-Hyp with a radiochemical purity of 99% after HPLC purification. In the Hyp added formulation, no macroscopic but minimal microscopic aggregation was observed. By TGC, selective accumulation in hepatic infarction and low uptake in viable liver of 123I‑Hyp/Hyp were detected, as confirmed by autoradiography and histology. Significantly higher doses of 131I-Hyp were delivered to necrotic (276‑93,600 mGy/MBq) than to viable (4.2 mGy/MBq) liver (P<0.05). In normal organs, 123I‑Hyp was eliminated within 24 h except for relatively high levels in the lungs and thyroid. Hepatobiliary elimination was a major pathway of 123I-Hyp causing high activity in the intestines. For both genders, dosimetry showed the longest residence time of 131I-Hyp in the remainder, followed by the lungs, intestines and thyroid. The highest absorbed radiation dose was seen in necrotic tissues and the shortest residence times and lowest absorbed radiation dose were found in the brain. 131I-Hyp selectively delivers higher radiation dose to necrosis compared with the rest of the body. Among normal organs, thyroids, lungs and intestines receive considerable radiation dose, which deserves cautious attention in developing this anticancer approach.
منابع مشابه
An overview of translational (radio)pharmaceutical research related to certain oncological and non-oncological applications.
Translational medicine pursues the conversion of scientific discovery into human health improvement. It aims to establish strategies for diagnosis and treatment of diseases. Cancer treatment is difficult. Radio-pharmaceutical research has played an important role in multiple disciplines, particularly in translational oncology. Based on the natural phenomenon of necrosis avidity, OncoCiDia has e...
متن کاملImproved therapeutic outcomes of thermal ablation on rat orthotopic liver allograft sarcoma models by radioiodinated hypericin induced necrosis targeted radiotherapy
Residual tumor resulting in tumor recurrence after various anticancer therapies is an unmet challenge in current clinical oncology. This study aimed to investigate the hypothesis that radioiodinated hypericin (131I-Hyp) may inhibit residual tumor recurrence after microwave ablation (MWA) on rat orthotopic liver allograft sarcoma models.Thirty Sprague-Dawley (SD) rats with hepatic tumors were di...
متن کاملBiodistribution and radiation dosimetry of [64Cu]copper dichloride: first-in-human study in healthy volunteers
BACKGROUND In recent years, Copper-64 (T1/2 = 12.7 h) in the chemical form of copper dichloride ([64Cu]CuCl2) has been identified as a potential agent for PET imaging and radionuclide therapy targeting the human copper transporter 1, which is overexpressed in a variety of cancer cells. Limited human biodistribution and radiation dosimetry data is available for this tracer. The aim of this resea...
متن کاملA Novel Biological Dosimetry Method for Monitoring Occupational Radiation Exposure in Diagnostic and Therapeutic Wards: From Radiation Dosimetry to Biological Effects
Background and Objective: Professional radiation workers are occupationally exposed to long-term low levels of ionizing radiation. Occupational health hazards from radiation exposure, in a large occupational segment of the population, are of special concern. Biological dosimetry can be performed in addition to physical dosimetry with the aim of individual dose assessment and biological effects....
متن کاملRabbit internal dosimetry for iodine-131 using GATE Monte Carlo simulation code: a preclinical trial
Introduction: One of the main concerns in administration of radiotracers, especially in therapeutic arm, is the amount of delivered dose to the different organs. Individual variations of anatomy, physiology and underlying pathology in the patients lead to alteration of administered activity. In the current study we preclinically applied internal dosimetry using an animal mod...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of oncology
دوره 44 3 شماره
صفحات -
تاریخ انتشار 2014