Intraoperative Vertebral Artery Angiography to Guide C1-2 Transarticular Screw Fixation in a Patient with Athetoid Cerebral Palsy
نویسندگان
چکیده
We present a case of an athetoid cerebral palsy with quadriparesis caused by kyphotic deformity of the cervical spine, severe spinal stenosis at the cervicomedullary junction, and atlantoaxial instability. The patient improved after the first surgery, which included a C1 total laminectomy and C-arm guided righ side unilateral C1-2 transarticular screw fixation. C1-2 fixation was not performed on the other side because of an aberrant and dominant vertebral artery (VA). Eight months after the first operation, the patient required revision surgery for persistent neck pain and screw malposition. We used intraoperative VA angiography with simultaneous fluoroscopy for precise image guidance during bilateral C1-2 transarticular screw fixation. Intraoperative VA angiography allowed the accurate insertion of screws, and can therefore be used to avoid VA injury during C1-2 transarticular screw fixation in comorbid patients with atlantoaxial deformities.
منابع مشابه
A novel method of C1–C2 transarticular screw insertion for symptomatic atlantoaxial instability using a customized guiding block
Atlantoaxial instability treated with the C1-2 transarticular screw fixation is biomechanically more stable; however, the technique demanding and the potential risk of neurovascular injury create difficulties for clinical usage, and there is still lack of clinical experience till now.We reported an adult female patient with symptomatic atlantoaxial instability due to rheumatoid arthritis that w...
متن کاملPosterior atlantoaxial fusion using a C2 transverse foramen-penetrating screw: A technical note
Background Although recent development of screw instrumentation techniques for rigid fixation of the atlantoaxial joint has increased surgical options, patients in whom screws of any type cannot be safely placed are sometimes encountered. We present a unique surgical technique for C1-2 transarticular screw placement utilizing a novel trajectory. Methods A 35-year-old male with a history of Do...
متن کاملBiomechanical analysis comparing three C1-C2 transarticular screw salvaging fixation techniques.
STUDY DESIGN This is an in vitro biomechanical study. OBJECTIVE To compare the biomechanical stability of the 3 C1-C2 transarticular screw salvaging fixation techniques. SUMMARY AND BACKGROUND DATA Stabilization of the atlantoaxial complex is a challenging procedure because of its complicated anatomy. Many posterior stabilization techniques of the atlantoaxial complex have been developed wi...
متن کاملAtlantoaxial transarticular screw fixation for a high-riding vertebral artery.
STUDY DESIGN The feasibility of inserting a screw for the narrow isthmus with a high-riding vertebral artery was evaluated in patients subjected to posterior atlantoaxial transarticular screw fixation. OBJECTIVE To demonstrate the feasibility of inserting bilateral screws and obtaining a stable atlantoaxial complex for patients with a high-riding vertebral artery. SUMMARY OF BACKGROUND DATA...
متن کاملVariation of the groove in the axis vertebra for the vertebral artery. Implications for instrumentation.
Transarticular screws at the C1 to C2 level of the cervical spine provide rigid fixation, but there is a danger of injury to a vertebral artery. The risk is related to the technical skill of the surgeon and to variations in local anatomy. We studied the grooves for the vertebral artery in 50 dry specimens of the second cervical vertebra (C2). They were often asymmetrical, and in 11 specimens on...
متن کامل