Improved photon-counting detector performance by intelligent management of detector deadtime

نویسندگان

  • Sergey V. Polyakov
  • Alan Migdall
  • I. P. Degiovanni
  • V. Schettini
چکیده

We discuss the difficulties of photon-counting at extremely high rates and introduce a scheme for a photon-counting detection system that addresses these difficulties. The method uses an array of N detectors and a 1-by-N optical switch with a control circuit to direct input light to live detectors. We compare performance of our system to other, passive detection systems and show that our detection system can handle incident photon rates higher than otherwise possible by suppressing the effects of detector deadtime. To support this claim, we present results of theoretical analysis and a proofof-concept experiment. In particular, both calculations and the experiment prove that a group of intelligently managed N detectors provides an improvement in operation rate that can exceed the improvement that would be obtained by either a single detector with deadtime reduced by 1/N, even if it were feasible to produce a single detector with such a large improvement in deadtime, or a passive beamsplitter tree system with N detectors. In addition to deadtime reduction, our scheme reduces afterpulsing as well as background counts (such as dark counts). We conclude that an intelligent active management of a group of N detectors is the best arrangement of photon-counting detectors to handle high photon rates, an important technological challenge for fast developing quantum metrology and quantum key distribution applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reduced Deadtime and Higher Rate Photon-Counting Detection using a Multiplexed Detector Array

Abstract We present a scheme for a photon-counting detection system that can be operated at incident photon rates higher than otherwise possible by suppressing the effects of detector deadtime. The method uses an array of N detectors and a 1-by-N optical switch with a control circuit to direct input light to live detectors. Our calculations and models highlight the advantages of the technique. ...

متن کامل

Calibrating photon-counting detectors to high accuracy: background and deadtime issues

When photon-counting detectors are calibrated in the presence of a background signal, deadtime effects can be significant and must be carefully accounted for to achieve high accuracy. We present a method for separating the correlated signal from the background signal that appropriately handles deadtime effects. This method includes consideration of pulse timing and afterpulsing issues that aris...

متن کامل

The dual-color photon counting histogram with non-ideal photodetectors.

Dual-color photon counting histogram (PCH) analysis utilizes the photon counts in two detection channels to distinguish species by differences in brightness and color. Here we modify the existing dual-color PCH theory, which assumes ideal detectors, to include the non-ideal nature of the detector. Specifically, we address the effects of deadtime and afterpulsing. Both effects modify the shape o...

متن کامل

Photon dosimetry based on selective data sampling for the NaI(TL) detector

Radiation detection is essential for determining of radiation dose. Depend on the detector and dosimetry method, detection process is performed in different levels. Pulse counting is the first level of detection. Typically, the output of a radiation detector for determining value of the radiation dose cannot be used directly. Through changing the response function or the readout detector, is tr...

متن کامل

Mean and variance of single photon counting with deadtime.

The statistics of photon counting by systems affected by deadtime are potentially important for statistical image reconstruction methods. We present a new way of analysing the moments of the counting process for a counter system affected by various models of deadtime related to PET and SPECT imaging. We derive simple and exact expressions for the first and second moments of the number of record...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007