Image Reconstruction in 3D Short-Scan SPECT

نویسندگان

  • Xiaochuan Pan
  • Chien-Min Kao
  • Charles Metz
  • Alexander Kiselev
چکیده

Physical factors such as photon attenuation degrade image quality and quantitative accuracy in single-photon emission computed tomography (SPECT). It is often considered (especially in situations with non-uniform attenuation and distance-dependent spatial resolution (DDSR)) that adequate compensation for the effects of these physical factors requires data acquired over 2 . However, as the analysis in this work suggests, one may need data acquired only over to correct adequately for the effects of some of the physical factors. Reduction of the scanning angle in SPECT imaging is desirable because it can reduce the scanning time and thus minimize patient-motion and other artifacts, and because scans over less than 2 can allow the detector to be rotated at a fixed distance closer to the patient. Also, in certain cases (e.g., in cardiac SPECT), one can choose the scanning angular range for obtaining maximum numbers of photons. This work focuses on investigation of accurate image reconstruction in 3D SPECT from data that are acquired with parallel-beam collimation only over and that contain the effects of photon attenuation (either uniform or non-uniform) and DDSR. For simplicity, we refer to such a scanning configuration as 3D short-scan SPECT. This work may have significant theoretical as well as practical implications for image reconstruction in SPECT. I. BACKGROUND Single-photon emission computed tomography (SPECT) is an important nuclear medicine imaging modality. Physical factors in SPECT such as photon attenuation and imperfect spatial resolution degrade image quality and quantitative accuracy [1,2] and should be adequately corrected for. Because these physical factors are generally spatially variant, it is often considered (especially in the situation with non-uniform attenuation and distance-dependent spatial resolution (DDSR)) that adequate compensation for the effects of these physical factors requires data measured at projection angles over 2 . However, as the analysis below suggests, it appears possible that (at least under certain conditions) data acquired only over can be used for adequately correcting for the effects of some physical factors such as photon attenuation. The reduction of the scanning angle in SPECT imaging is desirable because it can reduce scanning time and thereby minimize patientmotion and other artifacts. Also, in certain cases (e.g., in cardiac SPECT), one can choose the scanning angular range for obtaining maximum numbers of photons [3, 4]. This work focuses on investigation of accurate image reconstruction in 3D SPECT from data that are acquired with parallel-beam collimation only over and that contain the effects of photon attenuation (either uniform or non-uniform) and DDSR. For simplicity, we refer to such a scanning configuration as the 3D short-scan SPECT. II. MATHEMATICAL RATIONALES A. Redundant Information and Reduction of Scanning Angle In some tomographic imaging systems, the data measured over contain redundant information. One example is measurement of the 2D Radon transform [5], , of a real function over , where is the detector bin index and is the measurement angle. Such measurements contain redundant information because, in the absence of noise and other inconsistencies, the measurements from conjugate views are mathematically identical, i.e., (1) It is well known that such information can be exploited for reducing the scanning angle from to because the maximum difference between the values of the real angles on the two sides of Eq. (1) is . In fan-beam computed tomography (CT), the quantity is used to denote the measured transmission data, where indicates the detector bin index and the measurement angle. Although the fan-beam measurements (except for those with ) from conjugate views are not mathematically identical, one can still show that the fan-beam data acquired over contains redundant information, i.e., ! " $# (2) where # is a known and real function of , and its explicit form depends upon the detector configurations [6, 7]. It can be shown that %'&)( * $#

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Approach for Quantitative Evaluation of Reconstruction Algorithms in SPECT

ABTRACT Background: In nuclear medicine, phantoms are mainly used to evaluate the overall performance of the imaging systems and practically there is no phantom exclusively designed for the evaluation of the software performance.  In this study the Hoffman brain phantom was used for quantitative evaluation of reconstruction techniques. The phantom is modified to acquire t...

متن کامل

Performance Evaluation of FBP Reconstruction in SPECT Imaging

Introduction:  The  purpose  of  this  study  is  to  define  the  optimal  parameters  for  the  tomographic  reconstruction procedure in a routine single photon emission tomography. The Hoffman brain phantom  is modified to evaluate the reconstruction method. The phantom was imaged in a 3 and 2-dimensional  conformation and the results were compared.   Materials  and  Methods:  The  2D  phant...

متن کامل

Assessment of simulated patient motion and its effect on myocardial perfusion SPECT using two reconstruction methods (Filtered Backprojection;FBP and Iterative method) [Persian]

Introduction: Motion of the patient during myocardial perfusion SPECT could potentially results in false perfusion defects. The effect of different reconstruction methods on these artifacts is not studied. Clarification of the relation between the extent, severity and duration of motion with the resultant artifacts may be helpful in designing special soft wares for motion correction. This...

متن کامل

New approach for attenuation correction in SPECT images, using linear optimization

Background: Photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of SPECT images and results to errors in accuracy of quantitative measurements. This can be corrected via different physical or mathematical approaches. As the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘Piece ...

متن کامل

Image Reconstruction from 2D stack of MRI/CT to 3D using Shapelets

Abstract—Image reconstruction is an active research field, due to the increasing need for geometric 3D models in movie industry, games, virtual environments and in medical fields. 3D image reconstruction aims to arrive at the 3D model of an object, from its 2D images taken at different viewing angles. Medical images are multimodal, which includes MRI, CT scan image, PET and SPECT images. Of the...

متن کامل

Influences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3‐dimensional brain phantom

Objective: The aim of this study was to evaluate the influences of reconstruction and attenuation correction on the differences in the radioactivity distributions in 123I brain SPECT obtained by the hybrid SPECT/CT device. Methods: We used the 3-dimensional (3D) brain phantom, which imitates the precise structure of gray mater, white matter and bone regions. It was filled with 123I solution (20...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001