Non-contrast-enhanced MR Portography using spin labeling technique: comparison of balanced SSFP and half-Fourier FSE sequence
نویسندگان
چکیده
PURPOSE Several MRA techniques have been implemented for non-invasive imaging of the portal vein. A time-spatial labeling inversion pulse (time-SLIP) technique was reported using a free hand spatial selection and tag-on and tag-off alternating scan and MIP processing to only depict the marked blood while canceling the background signals at any specified inversion time [1]. The purpose of this study was to make a comparison between 3D balanced steady state free precession (SSFP) sequence and 3D half-Fourier FSE to explore the non-contrast-enhanced MR portography using spin labeling technique. MATERIALS AND METHODS The subject of this study was 50 consecutive patients (23 women, 27 men; mean age, 65.4 years, range 31-85) with pancreato-biliary disease. All examinations were performed on a 1.5-T magnet (EXCELART Vantage; Toshiba). The imaging protocol consisted of the following pulse sequences: a) 3D balanced SSFP sequence, TR/TE/TI=5/2.5/1300msec, flip angle=120. b) 3D half-Fourier FSE, TR/eTE/TI=2981~13110/80/1300msec, refocusing flip angle=160, matrix=256x256, thirty 3.5-mm section slices, respiratory triggering, parallel reduction factor=2.0, fat suppression. The time-SLIP pulse was placed to mark both the splenic and superior mesenteric vein that flows into the portal vein. The CNR of vessel to liver was calculated. Four radiologists who were blind to the clinical history performed the qualitative analysis (anatomic visualization, contrast of vessel to liver). Using contrast-enhanced CT images as truth, a receiver operating characteristics curve was generated and a statistical analysis of time-SLIP portography was performed. RESULTS The CNRs between the first branches and liver were higher in time-SLIP portography with the half Fourier FSE sequence (right; 3.49±1.72 , left; 3.03±1.12) than that in the portography with the SSFP (right; 3.30±1.61, left; 0.37±0.30). There was no significant difference between two sequences for the CNR of main portal trunk (FSE; 3.45±1.53, SSFP; 3.56±2.01). In the qualitative analysis, the contrast of intra-hepatic portal branches on the half-Fourier FSE was higher than that on the SSFP (FSE; 3.7±1.1, SSFP; 3.2±1.3). Anatomical visualization of main portal trunk in the SSFP images was better than that in the half-Fourier FSE. DISCUSSION AND CONCLUSION To investigate intra-hepatic portal branches, the MR Portography using half-Fourier FSE technique provides better quality images than that with SSFP sequence. The 3D balanced SSFP sequence is suitable for the investigation of main portal trunk because of lower burring artifacts. The MR Portography using the time-SLIP technique serves as a useful tool for screening procedures of portal vein. REFERENCES 1. Miyazaki M, Lee VS. Nonenhance MR angiography. Radiology 2008;248:20-43.
منابع مشابه
Time-Spatial Labeling Inversion Pulse: Safe, Simple and Effective Non-contrast MR Angiography
5. Shimada K, Isoda H, Okada T, et al. Noncontrast-enhanced hepatic MR angiography with true steady-state free-precession and time spatial labeling inversion pulse: optimization of the technique and preliminary results. Eur J Radiol. 2009;70(1):111-117. 6. Shimada K, Isoda H, Okada T, et al. Non-contrast-enhanced MR portography with time-spatial labeling inversion pulses: comparison of imaging ...
متن کاملBreast MRI Using a Balanced Steady-State Free Precession Imaging with a Two-Point Dixon Fat-Water Reconstruction Algorithm: Preliminary Experience and Comparison with 2D FSE
INTRODUCTION: Balanced steady-state free precession (b-SSFP) techniques yielding high SNR images in short scan times with T2-like image contrast have several appealing attributes for clinical breast MRI [1]. Clinical T2 imaging in the breast is routinely performed using a fat suppressed 2D Fast Spin Echo (FSE) pulse sequence with high in-plane spatial resolution. The 3-5 mm slice thickness obsc...
متن کاملNon-contrast-enhanced MR portography and hepatic venography with time-spatial labeling inversion pulses: comparison at 1.5 Tesla and 3 Tesla
BACKGROUND A 3 Tesla (3 T) magnetic resonance (MR) scanner is a promising tool for upper abdominal MR angiography. However, there is no report focused on the image quality of non-contrast-enhanced MR portography and hepatic venography at 3 T. PURPOSE To compare and evaluate images of non-contrast-enhanced MR portography and hepatic venography with time-spatial labeling inversion pulses (Time-...
متن کاملNon-contrast MR Angiography of the Toes: Correlations with Age and Gender
Purpose The aim of our study is to selectively visualize toe arteries without contrast media and exhibit correlations with age and gender. Non-contrast ECG-gated 3D half-Fourier FSE MR angiography with time-spatial labeling inversion pulses (time-SLIP) was investigated for efficacy in depicting the toe arteries using swap phase encode extended data (SPEED) acquisition. Materials and Methods All...
متن کاملNon-Contrast MRA
Introduction In MR angiography (MRA), techniques are mainly divided into contrast-enhanced MRA and non-contrast MRA. Various non-contrast MRA techniques are clinically useful and widely used in routine examinations, such as 3D TOF [1] in intracranial region, phase shift [2] for flow quantification, arterial spin labeling [3,4] in pulmonary vessels [5,6], and balanced SSFP [7] in bright blood ca...
متن کامل