[Effects of transmission counts on image quality during simultaneous emission/transmission scan].

نویسندگان

  • Kazumasa Inoue
  • Keiichi Oda
  • Masahiro Fukushi
چکیده

We compared the pre-injection transmission scan with the simultaneous emission/transmission scan (SET) using a body phantom in positron emission tomography (PET) to study the factors affecting emission (EMIS) images with different transmission (TRAN) data. The results showed that total count, region, scan method, and EMIS component influenced the bias and noise statistics. This influence was further passed on to the EMIS data and affected the reconstructed image. However, the result of fixing EMIS scan time at 10 minutes was that the noise statistics of EMIS had a greater effect on image quality than TRAN. The optimal scan counts of SET in this study were 20 Mcounts, with a scan time of about 10 minutes (85.5 MBq, (68)Ge-(68)Ga radioactivity). In clinical use, optimal collection count differs, as radiation TRAN quantity depends on the size of the subject, even with fixed radioactivity of (68)Ge-(68)Ga.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Statistical Image Reconstruction Methods for Simultaneous Emission/Transmission PET Scans

Transmission scans are necessary for estimating the attenuation correction factors (ACFs) to yield quantitatively accurate PET emission images. To reduce the total scan time, postinjection transmission scans have been proposed in which one can simultaneously acquire emission and transmission data using rod sources and sinogram windowing. However, since the post-injection transmission scans are ...

متن کامل

Review of transmission scanning configurations in cardiac SPECT

The diagnostic accuracy of single photon emission computed tomography (SPECT) is profoundly influenced by attenuation phenomenon. Soft tissue attenuation degrades cardiac SPECT image quality, thereby decreasing the possibility of the detection of the lesions. A variety of correction techniques based on different assumptions have been used to reduce the impact of attenuation. Several types of sy...

متن کامل

Transmission Imaging in Lymphoscintigraphy with a 153Gd Flood Source.

UNLABELLED Lymphoscintigraphy uses intradermal or interstitial injections of (99m)Tc-labeled tracers to produce images of focal lymph nodes. Because there is little or no anatomic information in the (99m)Tc images, a (57)Co flood source is sometimes used to provide transmission data along with the emission data. The anatomic shadow from the transmission scan generally improves interpretation an...

متن کامل

Fuzzy clustering-based segmented attenuation correction in whole-body PET imaging.

Segmented attenuation correction is now a widely accepted technique to reduce noise propagation from transmission scanning in positron emission tomography (PET). In this paper, we present a new method for segmenting transmission images in whole-body scanning. This reduces the noise in the correction maps while still correcting for differing attenuation coefficients of specific tissues. Based on...

متن کامل

Scan Time Optimization for Post-injection PET Scans

Previous methods for optimizing the scan times for PET transmission and emission scans under a total scan time constraint were based on linear non-statistical methods and used noise equivalent counts (NEC) criteria. The scan times determined by NEC analysis may be suboptimal when nonlinear statistical image reconstruction methods are used. For statistical image reconstruction, the predicted var...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nihon Hoshasen Gijutsu Gakkai zasshi

دوره 62 6  شماره 

صفحات  -

تاریخ انتشار 2006