Reaction of picrate with creatinine and cepha antibiotics.
نویسندگان
چکیده
The concentration of creatinine in serum, which is used to estimate glomerular filtration rate, is measured by reaction with alkaline picrate, but this reaction is not specific for creatinine. Although several other cephalosporin antibiotics have been reported not to react with picrate, we reacted picrate with creatinine, cefoxitin, penicillin, and eight different cephalosporins, and found that all compounds reacted with picrate and showed superimposable spectrophotograms with absorption maxima at 485 nm. From these results we conclude that the color-absorbing moiety of the product is the picrate molecule. Further, the structure common to creatinine and the cephalosporins, cefoxitin, or penicillin is the carbonyl group attached to a nitrogen and a carbon atom. We postulate that the carbonyl group with the adjacent carbon and nitrogen atoms is probably the chemical moiety that reacts with picrate to absorb energy at 485 nm.
منابع مشابه
Mechanism of cefoxitin and cephalothin interference with the Jaffé method for creatinine.
Some cepha antibiotics interfere positively in the Jaffé method for determining creatinine. The extent of this interference differs with the modification used, and its mechanism is unknown. We studied the spectrophotometric and thermodynamic properties of the reaction of picrate with creatinine and two cepha antibiotics, cefoxitin and cephalothin. The absorbance spectra of the chromophore produ...
متن کاملPositive interference with the Jaffé reaction by cephalosporin antibiotics.
Cephaloglycin, cephalothin, cephaloridine, cefoxitin, and cephacetrile are cephalosporin antibiotics that react with alkaline picrate solution to give a creatinine-like response. The mechanism of this reaction is not known, and several structurally similar compounds do not react under these same conditions. Because large quantities of a cephalosporin antibiotic may be administered to a patient ...
متن کاملKinetic potentiometric determination of creatinine in serum with a picrate ion-selective membrane electrode.
We describe a new kinetic method for potentiometric determination of creatinine in serum, based on the creatinine--picrate reaction in alkaline medium (Jaffé reaction). The reaction is monitored with a picrate-selective electrode, and the increase in electrode potential during 270 s is measured and related directly to the creatinine concentration. Small cation-exchange columns are used to separ...
متن کاملNitromethane interferes in assay of creatinine by the Jaffé reaction.
A patient who ingested a methanol/nitromethane mixture (model airplane fuel) showed an apparent plasma creatinine concentration of 8.0 mmol/L by the Jaffé reaction when the actual creatinine concentration, as measured by a specific enzymatic method, was 0.09 mmol/L. This effect was due to nitromethane in the plasma. Interference by nitromethane with the determination of creatinine by reaction w...
متن کاملAutomated reaction-rate method for determination of serum creatinine with the CentrifiChem.
An automated kinetic method to determine creatinine in serum with the Jaff#{233} reaction is described. The method does not require deproteinization or adsorption of creatinine on Fuller’s earth or ion.exchange resin. A maximum of 29 serum samples, standards, and control sera can be assayed in less than 1.5 mm. Interferences by most of the known Jaff#{233}-positive serum constituents were studi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 30 10 شماره
صفحات -
تاریخ انتشار 1984