Detection of Cd(II) using antibody-modified microcantilever sensors.
نویسندگان
چکیده
This work demonstrated the feasibility of detecting divalent Cd(II) ions using antibody-modified microcantilever (MCL) sensors. Different surface modification methods were compared and multilayer approach was found superior than others for MCL surface modifications for antibody-based Cd(II) sensor development. When the Cd(II)-EDTA complex sample is injected into the fluid cell where the MCL is held, the MCL bends upon the recognition of the Cd(II) complex by the antibody on the surface of the MCL. Control experiments showed that complex that does not contain Cd(II) did not cause any bending of the MCL. The detection limit of the sensor was approximately 10(-9) M. The reaction rate analysis indicated that Langmuir adsorption model is appropriate to describe the absorption of Cd(II)-EDTA-BSA on the antibody-covered MCL surface.
منابع مشابه
Analysis of Deflection Enhancement Using Epsilon Assembly Microcantilevers Based Sensors
The present work analyzes theoretically and verifies the advantage of utilizing ɛ-microcantilever assemblies in microsensing applications. The deflection profile of these innovative ɛ-assembly microcantilevers is compared with that of the rectangular microcantilever and modified triangular microcantlever. Various force-loading conditions are considered. The theorem of linear elasticity for thin...
متن کاملDisposable screen-printed sensors modified with bismuth precursor compounds for the rapid voltammetric screening of trace Pb(II) and Cd(II).
In this article, a study of novel screen-printed electrodes bulk-modified with five potential bismuth precursor compounds (bismuth citrate, bismuth titanate, bismuth oxide, bismuth aluminate and bismuth zirconate) is presented for the determination of Cd(II) and Pb(II) by anodic stripping voltammetry. During the electrolytic deposition step, the precursor was reduced and served as the source of...
متن کاملAn anti E. coli O157:H7 antibody-immobilized microcantilever for the detection of Escherichia coli (E. coli).
A silicon microcantilever sensor was developed for the detection of Escherichia coli O157:H7. The microcantilever was modified by anti-E. coli O157:H7 antibodies on the silicon surface of the cantilever. When the aquaria E. coli O157:H7 positive sample is injected into the fluid cell where the microcantilever is held, the microcantilever bends upon the recognition of the E. coli O157:H7 antigen...
متن کاملChemically-Modified Activated Carbon with L-Arginine for Selective Solid Phase Extraction and Preconcentration of Metal Ions
In this study, a new sorbent of chemically-modified activated carbon with L-arginine (AC-Arg) has been produced as solid-phase extraction, to trace Zn(II) and Cd(II) ions in real samples, including soil and water samples, by Flame Atomic Absorption Spectrometry (FAAS). Once the surface coverage value is determined, the surface modification has been investigated and assessed, while having em...
متن کاملAdsorption of Ni(II) and Cd(II) from Aqueous Solutions Using Modified Rice Husk
Background and purpose: Recently, release of pollutants such as heavy metal ions to the environment becomes one of the most important problems for soil and water. The present study was conducted to introduce modified rice husk (RH) as a new low-cost adsorbent. Materials and Methods: In this study, tartaric acid modified RH (TARH), was used as an adsorbent for removal of Ni(II) and Cd(II) from w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultramicroscopy
دوره 107 12 شماره
صفحات -